Beckett GeniSys 24V 7559 User Manual

Advanced 24 vdc burner control

Advertisement

Quick Links

GeniSys
24V
Model 7559
PARTS & ACCESSORIES
Advanced 24 Vdc Burner Control
Description / Applications
The Beckett GeniSys
24V Advanced Burner Control is a
TM
24 Vdc primary safety control for oil burners used in special
applications including, but not limited to, water heaters,
pressure washers, crack sealers and portable heaters having
fi ring rates less than 5.5 GPH. The GeniSys
24V is used
TM
with a suitable cad cell fl ame sensor to control the oil burner
motor, igniter, and optional solenoid valve. It has 24 volt enable
input compatible with mechanical and high limit switches. It
can provide interrupted or intermittent duty ignition, and it has
a 15 second lockout time on fl ame failure.

Advertisement

Table of Contents
loading

Summary of Contents for Beckett GeniSys 24V 7559

  • Page 1 Model 7559 PARTS & ACCESSORIES Advanced 24 Vdc Burner Control Description / Applications The Beckett GeniSys 24V Advanced Burner Control is a 24 Vdc primary safety control for oil burners used in special applications including, but not limited to, water heaters, pressure washers, crack sealers and portable heaters having fi...
  • Page 2: Specifications

    15 sec 8 min battery in four to six weeks. Valve-on delay and motor-off delay timings on all models are programmable with the Beckett Contractor Tool. Other factory Environmental Ratings: set timings are available. Contact Beckett for alternate • timings.
  • Page 3: Electrical Shock Hazard

    Installation/Operation/Maintenance Explosion, Fire, Professional WARNING WARNING Scald, & Burn Hazard Service Required. Incorrect installation or misuse of this All heating equipment must control could result in severe personal have HIGH LIMIT controls to injury or death from heavy smoke, protect against excessive explosion or fi...
  • Page 4 Figure 1 – Getting to know the control Wiring Connections Communication Port 7.5 amp Fuse Cad Cell for Igniter, Connections Control, Valve and Alarm 20 amp Motor Fuse Figure 2 – Typical Wiring for Interrupted Ignition (With or without Valve-on Delay or Motor-off Delay.) VALVE ALARM...
  • Page 5: Control Operation

    ■ Wiring: End the call for heat. Verify that the burner turns off before leaving the installation site. Incorrect Wiring Will CAUTION ■ Check Safety Features Result in Improper Control Operation ○ Safe Start Check GeniSys 24V wiring label colors may Place a jumper across the cad not match the wire colors of the burner cell terminals.
  • Page 6: Sequence Of Operation

    Sequence of Operation seconds on, 5 seconds off, 3 times Fire Hazard WARNING before locking out. To reset the control from lockout Reset and Service by Qualifi ed interrupt power for at least 2 seconds. Technician only. Ignition Carryover: Once fl ame is established, the igniter remains on for Burner States 10 additional seconds to ensure fl...
  • Page 7: Maintenance

    ■ Priming the Pump To reset, interrupt power for at least 2 seconds. Hot Gas Puff-Back & Always verify the control functions WARNING according to all specifi cations before Heavy Smoke Hazard leaving the installation site. Failure to bleed the pump properly could result in unstable combustion, hot gas Replace the control if it does not puff-back and heavy smoke.
  • Page 8: Limited Warranty Information

    BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE OF ANY NATURE. Beckett neither assumes, nor authorizes any person to assume for Beckett, any other liability or obligation in connection with the sale of this equipment. Beckett’s liability and Customer’s exclusive remedy is limited to the cost of the product.

Table of Contents