Baldor DSM S Series Installation Manual page 31

Dsm s-series integrated stepper motor / driver
Table of Contents

Advertisement

Microstep Resolution Select (MSEL)
The MSEL parameter specifies the microstep resolution of the DSM. The following table lists
valid MSEL parameter settings:
MSEL value: Steps per revolution
10 2000
16 3200
25 5000
32 6400
50 10000
Motor Run Current (MRC)
The Motor Run Current (MRC) parameter sets the motor run current to a percentage of the full
output current of the DSM driver section.
Hold Current Delay Time (HCDT)
The HCDT parameter sets the delay time between the last clock pulse and the application of
the holding current.
Motor Hold Current (MHC)
The MHC parameter sets the motor hold current as a percentage of the full output current of
the driver. If the hold current is set to 0, the output circuitry of the driver section will disable
when the hold current setting becomes active. Following the last step clock pulse, the hold
current setting becomes active after the period specified by HCDT.
Direction Override (DIR)
The DIR parameter changes the motor direction relative to the direction input signal, adapting
the direction of the DSM to operate as your system requires.
Factory button
The Factory button resets each parameter in the software to factory default values. Click Set
to apply these values.
Recall! and Upgrade! menu options
The Recall! option uploads the existing parameter settings from the DSM.
The Upgrade! option (if present) must not be used! It currently has no purpose and will
erase the firmware on the DSM, leaving it inoperable. If you have accidentally selected the
Upgrade! option, please contact Baldor customer support.
MN1940
1 200
2 400
4 800
5 1000
8 1600
MSEL value: Steps per revolution
64 12800
100 20000
108 21600
(1 microstep = 1 arc minute)
125 25000
127 25400
(1 microstep = 0.001 mm)
128 25600
180 36000 (1 microstep = 0.01°)
200 40000
250 50000
256 51200
www.baldormotion.com
Operation 5-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsms 17Dsms 23Dsms 34

Table of Contents