2.3.5

Connecting the Indoor-to-Outdoor Cable

2.3.5.1
Units with an Installed Waterproof Seal (not applicable to
new ODU)
To connect the indoor-to-outdoor cable:
Remove the two screws holding the waterproof seal to the outdoor unit and
1
remove the waterproof seal.
Unscrew the top nut from the waterproof seal.
2
Route a straight Category 5E Ethernet cable (8-wire, 24 AWG) through both
3
the top nut and the waterproof seal.
NOTE
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of
approved cables and length limitations in section 2.1.2.
Insert and crimp the RJ-45 connector. Refer to Appendix D for instructions
4
on preparing the cable.
Connect the Ethernet cable to the outdoor unit RJ-45 connector.
5
Replace the waterproof seal and then the top nut. Make sure that the external
6
jack of the cable is well inside the waterproof seal to guarantee a good seal.
Route the cable to the location selected for the indoor equipment.
7
Assemble an RJ-45 connector with a protective cover on the indoor end of the
8
indoor-to-outdoor cable.
Installation

Figure 2-10: The Waterproof Seal

Installing the Outdoor Unit
49