Indoor Unit Verification

To verify the correct operation of the indoor equipment, examine the LED
indicators located on the top panel of the SU IDU and AU IDU units, or on the
front panel of the BS-AU module.
Table 3-7 provides information for the BS-AU IDU LEDs. Table 3-8 lists the LEDs
of the PS1073 IDU.
Name
W-LINK
ODU CURRENT
CONSUMPTION
ODU STATUS
IDU PWR
ALARM
Commissioning

Table 3-7: BS-AU LEDs

Description
Wireless link activity
Current Consumption of
the Outdoor Unit
Outdoor Unit Self-test
Power indication for the
Indoor Unit
Indoor Unit Alarm
Indication
Operation Verification
Functionality
Green - At least one SU is associated.
Blinking Red - No SU is associated.
Off - Wireless link is disabled.
Red - over current.
Blinking Red - open circuit or below
anticipated current consumption.
Green - within tolerance.
Green - Self test passed and ODU
ready for operation.
Blinking Amber - Testing (not ready
for operation)
Red - fatal failure.
Green - IDU power is OK.
Off - no power is supplied to the IDU.
Red - a fatal failure indication.
Off - IDU is functioning properly.
83