The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
<9/12 kBtu/h class>
Chassis
Hook
90(3 17/32)
Ø70mm
Left rear piping
<18 kBtu/h class>
Chassis
Hook
Ø70mm
133mm
Left rear piping
Installation
Installation Plate
Type "A"
70(2 3/4)
Ø70mm
Right rear piping
Installation Plate
Type "A"
Ø70mm
100mm
Right rear piping
Installation Manual 15