Download Print this page
Intel S5500BC - Server Board Motherboard Quick Start User Manual
Intel S5500BC - Server Board Motherboard Quick Start User Manual

Intel S5500BC - Server Board Motherboard Quick Start User Manual

Quick start guide
Hide thumbs Also See for S5500BC - Server Board Motherboard:

Advertisement

Quick Links

Intel® Server Board S5500BC
Quick Start User's Guide
Thank you for buying the Intel® Server Board
S5500BC. The following information will help
you integrate your new server board into a server
chassis. The Intel® Server Board S5500BC is designed
for use with the Intel® Server Chassis SC5650.
For details on these chassis or to select a third party chassis,
please visit
http://www.intel.com/go/serverbuilder
and
http://support.intel.com/support/motherboards/server.
When installing the server board into a reference chassis,
refer to the reference chassis instructions.
User Guides are also available on the Intel ® Server Deployment Toolkit
3.0 CD that accompanied your Intel ® Server Board S5500BC.
If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration,
please see the Intel ® Server Board S5500BC User's Guide, available on the Intel ® Server Deployment
Toolkit 3.0 CD or at http://support.intel.com/motherboards/server/s5500BC.
Please boot to the Intel ® Server Deployment Toolkit 3.0 CD first for BIOS and firmware configuration and updates.
Read all cautions and warnings first before starting your server system integration.
4
Warning
Install the Server Board
Read all caution and safety
statements in this document
IMPORTANT NOTE: If you are using a non-Intel server chassis, see your
before performing any of the
chassis documentation for preparatory steps prior to server board installation.
instructions. Also see the Intel ®
A. Insert the Server Board
Server Board and Server Chassis
Safety Information document at:
Place the board into the chassis, making sure that back panel I/O openings and
http://support.intel.com/support/
chassis standoffs align correctly.
motherboards/server/sb/cs-010770
®
When using the Intel
Server Chassis SC5650, insert the front of the board
.htm
for complete safety information.
first, then slide the board back so the I/O connectors fit through the I/O
openings at the rear of the chassis.
Warning
Installation and service of
this product should only be
performed by qualified service
personnel to avoid risk of injury from
I/O Openings
electrical shock or energy hazard.
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
Install the Processor(s) continued
integration to avoid possible
damage to server board and/or
E. Install the Processor
other components.
Tools Required
CAUTION: The underside of the
processor has components that
may damage the socket wires if
installed improperly.
Components
Processor must align correctly with
the socket opening before installation.
Phillips*
Anti-static
screwdriver
wrist strap
DO NOT DROP processor into socket!
Fastener Identification Guide
E52682-004
Intel is a registered trademark of Intel Corporation or its
subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property
of others. Copyright © 2008, Intel Corporation. All rights
reserved.
B. Attach the Server Board
The directions below are for the Intel
®
Server Chassis SC5650.
For a non-Intel server chassis, use the fasteners that came with your chassis.
Use screws to attach the board to the chassis at the 8 locations indicated by the
solid blue arrows in the figure [ ].
Intel
Server
®
Intel
®
Server Chassis
Chassis SC5650
SC5650 Shown
Intel Server
Chassis
Front of
Fastener
Board
F. Close Load Plate and Socket Lever
A
Close the load
A
Orient the processor with the socket
plate all the way
A
so that the processor cutouts match
as shown.
the two socket pins.
Install the processor as shown.
B
With your finger, push down
on the load plate as shown.
A
C
Close the socket lever and ensure that the
load plate tab engages under the socket
lever when fully closed.
C
B
Minimum Hardware Requirements
To avoid integration difficulties and possible board damage, your system must meet the
following minimum requirements:
• Processor: Intel
®
Xeon
®
Processor 5500 Series with compatible heat sink.
• Memory Type: Minimum of one 1 GB, 240-pin DDR3 800/1066/1333 MT/s RDIMM or UDIMM.
• Power: Minimum of 400 W with 3A of standby current, which meets the SSI EPS 5V specification.
1
Preparing the Chassis
If using a non-Intel server chassis, refer to the documentation that came with your
chassis for preparatory steps.
Observe normal ESD (ElectroStatic Discharge) procedures.
Place your Intel
®
Server Chassis and Intel
®
Server Board on a flat anti-static surface
to perform the following integration procedures. Always touch the chassis frame
first, before reaching inside to install the server board, make server board
connections or install other components.
3
Install Server Board Bumpers
IMPORTANT NOTE: If you are using a non-Intel server chassis, see your chassis documentation
for preparatory steps prior to server board installation. If you are using an Intel
Chassis, use the bumpers that came with the chassis.
Prepare Server Board
A
Rotate board to show underside
and hold upright as shown.
A
B
CAUTION: To avoid
damage to the board, do not
lay flat with the component
side down.
B
Locate the five circles as shown.
Attach the Bumpers
C
C
Remove the backing from each
bumper.
D
Press a bumper onto each of
the five circles.
5
Install the Processor(s)
A. Open the Socket Lever
Cautions:
A
Push the lever handle down
1. When opening a socket, DO NOT TOUCH
and away from the socket to
the gold socket wires.
release it.
B
Rotate the lever open all
2. When unpacking a processor, hold by the
the way.
edges only to avoid touching the gold
contact wires.
A
B
6
Install Active Heat Sink(s)
An active heat sink is required for the Intel
®
Server Chassis
SC5650 DP and BRP.
A typical active heat sink is shown below.
Note: Heatsink
For a non-Intel chassis, see the documentation
styles may vary
accompanying your chassis.
CAUTION: The heat sink has thermal interface
material (TIM) on the underside of it. Use caution
so that you do not damage the thermal interface
material. Use gloves to avoid sharp edges.
A
A
If a protective film covers the thermal interface material (TIM) on the
underside of the heatsink, remove the protective film.
B
Align heatsink fins to the front and back of the chassis for correct airflow.
Airflow goes from front-to-back of chassis.
See airflow diagram at right.
Each heatsink has four captive fasteners and should be tightened as follows:
C
Using a #2 Phillips* screwdriver, finger-tighten each fastener diagonally,
according to the white-circled numbers.
D
Securely re-tighten each fastener again in the same order as performed in Step C.
E
Attach fan power cable to server board as shown.
2
Installing the I/O Shield and Attach I/O Labels
Note: The I/O shield and label installation procedures shown below apply to the
Intel
®
Server Chassis SC5650.
Attach the Labels to the I/O Shield (optional)
Note: Make sure you install the labels on the correct side
of the I/O shield. Note the orientation of the cutouts
in the drawing before attaching your labels.
A
Remove the backing from one of the three I/O
shield labels included with your server board.
B
Press the label onto the I/O shield as shown.
C
Repeat steps to install the second and third I/O shield labels.
Install the I/O shield
Shield installs from inside
Chassis Back
of chassis. The labels
Panel Opening
should be visible from the
outside of the chassis.
A
Insert one side edge of
shield as shown.
B
Push shield firmly into
chassis opening until it
A
clicks into place.
®
Server
D
B. Open the Load Plate
C. Remove Socket Protective Cover
A
A
Push the rear tab with your
Grasp the socket protective cover
finger tip to bring the front
by the two tabs and carefully lift straight
end of the load plate
up as shown.
up slightly.
A
1. To avoid damage, DO NOT
DROP the cover onto the
socket wires or components.
Save the protective cover.
B
Open the load plate as shown.
B
CAUTION: Do not
over-tighten fasteners.
3
C D
1
2
TIM
4
E
Labels on outside
face of I/O shield
ID
NI C1
NI C2
®
Intel
Server
Chassis SC5650 shown
B
D. Remove the
Processor
Protective Cover
A
Take the processor out
of the box and remove
the protective shipping
cover.
A
Intel
®
Server Chassis SC5650
Airflow Diagram
LOCK
Airflow
B
Airflow

Advertisement

loading