Installation

6.1

Rack mounting

The packaging of your mixing console contains two 19" rack mounts for
installation on the side panels of the console.
Before you can attach the rack mounts to the mixing console, you need to remove
the screws holding the left and right side panels. Then, use these screws to
fasten the two rack mounts, each specifically to one side. With the rack mounts
installed, you can mount the mixing console in a commercially available 19" rack.
Be sure to allow for proper air flow around the unit, and do not place the mixing
console close to radiators or power amps, so as to avoid overheating.
Only use the screws holding the mixing console side panels to fasten
the 19" rack mounts.
6.2

Cable connections

You will need a large number of cables for the various connections of the console.
The illustrations below show the wiring of these cables. Be sure to use only
high-grade cables.
¼" TS footswitch connector
The footswitch connects both poles momentarily
Fig. 6.1:
Foot switch connector
6.2.1
Audio connections
Please use commercial RCA cables to wire the 2-track inputs and outputs.
You can, of course, also connect unbalanced devices to the balanced
input/outputs. Use either mono plugs, or use stereo plugs to link the ring
and shaft (or pins 1 & 3 in the case of XLR connectors).
behringer.com
strain relief clamp
sleeve
tip
sleeve
pole 1/ground
tip
pole 2
Balanced use with XLR connectors
2
1
3
input
1 = ground/shield
2 = hot (+ve)
3 = cold (-ve)
1
2
3
output
For unbalanced use, pin 1 and pin 3 have to be bridged
Fig. 6.2:
XLR connections
Caution! You must never use unbalanced XLR connectors
(PIN 1 and 3 connected) at the MIC input jacks if you want to use the
phantom power supply.
Unbalanced ¼" TS connector
Fig. 6.3:
¼" mono plug
Strain relief clamp
Sleeve
Tip
Sleeve
(ground/shield)
Tip
(signal)