70
Hardware Maintenance Manual
Diagnostic Error Code
020-198-XXX
PCI test aborted
020-199-XXX
PCI test failed, cause unknown
020-262-XXX
PCI system error
025-000-XXX
IDE interface Test Passed
025-00X-XXX
025-01X-XXX
IDE interface failure
025-027-XXX
IDE interface Configuration/Setup error
025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE Interface failure
025-195-XXX
IDE interface Test aborted by user
025-196-XXX
IDE interface test halt, error threshold
exceeded
025-197-XXX
IDE interface test warning
FRU/Action
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 53
2. Flash the system and re-test. See "Flash
update procedures" on page 516
3. Go to "Undetermined problems" on page
88
1. Go to "Undetermined problems" on page
88
2. Flash the system and re-test. See "Flash
update procedures" on page 516
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
1. IDE signal cable
2. Flash the system. See "Flash update
procedures" on page 516
3. Reseat IDE signal cable
4. IDE device
5. System board
1. IDE signal cable
2. Check power supply
3. Reseat IDE signal cable
4. IDE device
5. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 53
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test

Hide quick links: