Download Print this page

Whirlpool WGD4750X Product Dimensions

Whirlpool 29" and 27" wide model gas dryer

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
WGD4750X, WGD4800X, WGD4900X,
WGD5500X, WGD5550X, WGD5600X,
WGD5700X, WGD4850X, WGD4890X,
WGD5610X
Gas supply: This dryer is equipped for use with Natural gas. Dryer
can be converted to L.P. gas. When rigid pipe is used it should be
1/2" IPS. When acceptable to the gas supplier and local codes, 3/8"
approved tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-
joint compounds resistant to the action of L.P. gas must be used.
An individual manual shutoff valve must be installed within 6 ft (1.8
m) of the dryer in accordance with the National Fuel Gas Code ANSI
Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical
supply is required. A time-delay fuse or circuit breaker and a
separate circuit are recommended.
Water (Steam models only): The dryer must be connected to the
cold water faucet using new inlet hoses. Do not use old hoses. Do
not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent must
be used. Do not use plastic or metal foil vet. Exhaust hood must be
at least 12" (305 mm) from the ground or any object that may be in
the path of the exhaust.
Hood styles: A & B are recommended.
B
4"
(102 mm)
A
4"
(102 mm)
A. Louvered hood
B. Box hood
4"
C. Angled hood (acceptable)
(102 mm)
The vent system chart provides venting requirments that will help to
achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations for 27" have a 90° turn
inside the dryer. To determine maximum exhaust length, add one 90°
turn to the chart.
Vent System Chart
Number of
Type
Box/louvered
90° turns or
of vent
elbows
0
Rigid metal
64 ft. (20 m)
1
Rigid metal
54 ft. (16.5 m)
2
Rigid metal
44 ft. (13.4 m)
3
Rigid metal
35 ft. (10.7 m)
4
Rigid metal
27 ft. (8.2 m)
Vent System Chart
(29" Wide Long Vent Models Only)
Number of
Type
90° turns
of vent
or elbows
0
Rigid metal
Installation Spacing
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
5
Rigid metal
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
29" and 27" Wide Model Gas Dryer
C
2½"
(64 mm)
Angled
hoods
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Box/louvered, or
Angled hoods
120 ft. (36.6 m)
110 ft. (33.5 m)
100 ft. (30.5 m)
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use
90 ft. (27.4 m)
the fewest number of elbows and turns. Use the fewest 90° turns possible.
80 ft. (24.4 m)
Do not use vent runs longer than specified in vent length chart.
70 ft. (21.3 m)
Determine the number of elbows you will need.
OVERALL DIMENSIONS
29" Wide Model Dryer dimensions
Installation Spacing
18"*
(457 mm)
1"
29"
1"*
27
1"
¾"
(737 mm)
(25 mm)
(25 mm)
(25 mm)
(705 mm)
A
B
27" Wide Model Dryer dimensions
23¾"
(603 mm)
43 "
(1092 mm)
*29
1
/
"
2
(749 mm)
27"
(687 mm)
A
Installation Spacing
18"*
(457 mm)
1"
27"
1"
1"*
(686 mm)
(25 mm)
(25 mm)
(25 mm)
(743 mm)
A
*Required spacing
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
For closet installation, with a door,
the minimum ventilation openings in
the top and bottom of the door are
required. Louvered doors with
equivalent air ventilation openings
are acceptable.
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
3"*
(76 mm)
14" max.*
48 in.
2
*
(356 mm)
2
(310 cm )
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*
3"*
24 in.
2
2
(76 mm)
(155 cm )
C
43 "
(1092 mm)
13¾"
(349 mm)
*29
1
/
"
2
(749 mm)
27"
(687 mm)
A. Large opening side-swing door
B
B. Wide opening hamper door
(76 mm)
14" max.*
2
48 in.
*
(356 mm)
2
(310 cm )
*
2
24 in.
2
(155 cm )
(76 mm)
29
5
¼"
½"*
(140 mm)
B
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
3"*
3"*
Ref. W10096984A
01/2011

Advertisement

loading

This manual is also suitable for:

Wgd4800xWgd4900xWgd5500xWgd5550xWgd5600xWgd5700x ... Show all