Oki MB451wMFP User Manual page 171

All-in-one printer
Hide thumbs Also See for MB451wMFP:
Table of Contents

Advertisement

Open the top cover and remove the used
1
image drum.
Remove the image drum upward slowly.
If the image drum is removed, the toner
cartridge is also removed.
Memo
 When making duplex copies using the document glass, the
continuous scan mode is automatically enabled. Follow the
on-screen instructions.
Be sure not to throw used image
drum and toner cartridges into
fire; toner in the cartridges may
WARNING
scatter and ignite, causing burn
injuries.
Install a new image drum.
2
Take the new image drum out of the wrapping
bag. Remove the silica gel.
Silica gel
Note
 Always use a new image drum. An image drum that has
been attached or used on another printer cannot be used.
Align both guide posts of the image drum with
their guide grooves on the printer, and gently
set the image drum into the printer.
Guide Post
Turn the lever in the direction shown.
Note
 The image drum (the green cylinder) is very delicate.
Handle it with extreme care.
 Do not expose the image drum to direct sunlight or bright
interior light (approximately 1,500 lux or more). When
leaving it under normal interior light for 5 minutes or
more, cover it with black paper.
 Do not leave the image drum for more than 1 hour, even if
it is covered with black paper.
Close the top cover.
3
- 171 -
Replacing Consumable Items
Guide Grooves
Guide Post
8

Advertisement

Table of Contents
loading