SA-FT1H/WPFT1/SS-CNPFT1/MSPFT1/SRPFT1
SS-CNPFT1 (center speaker)
Speaker system
Speaker units
Enclosure type
Rated impedance
Power handling capacity
Maximum input power:
Sensitivity level
Frequency range
Dimensions (w/h/d)
with table top stand
Mass
with table top stand
SA-WPFT1 (subwoofer)
Speaker system
Speaker units
Enclosure type
Reproduction frequency range
Continuous RMS power output 120 W (6 ohms 80 Hz,
Input
LINE IN (input pin jack)
General
Power requirements
Power consumptions
Dimensions (w/h/d)
Mass
Supplied accessories
Speaker cord (short) (3)
Speaker cord (long) (2)
Audio connecting cord (1)
Table top stand cover (4)
Table top stand base (4)
Cushion (8)
Rear pad (16)
Screw (M5) (4)
Screw (M3) (8)
Design and specifications are subject to change without notice.
2
2 way, magnetically
shielded
Woofer: 3 × 12 cm (× 2),
cone type
Tweeter: 2.5 cm, balanced
dome type
Bass reflex
8 ohms
110 W
84 dB (1 W, 1 m)
150 Hz - 50,000 Hz
Approx. 430 × 45 × 44 mm
Approx. 430 × 56 × 50 mm
Approx. 0.5 kg
Approx. 0.6 kg
Active subwoofer,
magnetically shielded
Woofer: 20 cm, cone type
Acoustically Loaded
Bass reflex
30 Hz - 180 Hz
10% THD)
120 V AC, 60 Hz
70 W
0.3 W (standby mode)
Approx. 430 × 408 × 187 mm
Approx. 10 kg
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The "limit" indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a
passive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE
WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS
WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS
MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
AC
1.5k Ω
voltmeter
(0.75V)
Earth Ground

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ft1hSa-wpft1Ss-cnpft1Ss-mspft1Ss-srpft1

Table of Contents