K-4 keypad is mandatory when some options are selected. *
Filter cycles
Digital control pad lockout
The system automatically performs 2 filter cycles per day, at 12-
This function allows you to prevent unauthorized parameter setting
hour intervals. During a filter cycle, Pumps 2 & 3 and blower run
of the unit. This feature is especially helpful when young children
for one minute. Pump 1 then runs at low speed for the remaining
have access to the keypad.
of the cycle and "Filter Cycle" icon lights up. (If system is equipped
There are two modes you can choose from: Full lock or Partial lock.
with a circulation pump, all pumps and blower run for one minute.
Full lock means that all keypad functions are locked. Partial lock
Circulation pump then runs for the remaining of the cycle and
means that the basic functions of the spa will remain accessible
"Filter Cycle" icon lights up.)
(pumps, blower and light), but it will be impossible to change the
Setting filter cycles:
temperature Set Point, to override the Economy mode or to
enter the Programming mode.
1- Press Filter key.
When control pad is locked, the "Lock" icon will be displayed.
2- The display will show FDxx, with "xx"
FD10
representing the duration in hours.
Locking your digital control pad:
3- Use Up and Down arrows to change setting.
4- Press Filter key again.
1- Press and hold Econo key for 5 seconds.
5- The display will show FSxx, with "xx"
2- The display will show LocP, with "P"
FS06
LocP
representing the delay before cycle starts.
representing Partial lock.
6- Use Up and Down arrows to change setting.
3- Release key and keypad will be in Partial lock
LocF
7- Press Filter key to store settings.
mode. Keep key pressed down for 5 more
seconds if you want to be in Full lock mode.
40-minute filter cycle time-out: If you turn a pump, blower or
The "LocF" message will then be displayed.
light on during a filter cycle, the cycle will be interrupted and will
only resume 40 minutes after the system has turned the last active
When control pad is locked, all automatic functions of the system run
output off.
as usual. If a key is pressed down, a "LocP" or "LocF" message will be
displayed for 1 second. To unlock the keypad, simply press and hold
Econo key again for 5 seconds.
Purge cycles
Economy mode
The system can perform a number of purge cycles per day.
During a purge cycle, pumps and blower run for two minutes
and "Filter Cycle" icon lights up.
To save energy, the Economy mode Set Point is 11˚C (20˚F)
below the Normal mode Set Point.
Setting purge cycles:
The "Economy Mode" icon lights up when Economy
1- Press Filter key.
mode is on.
2- The display will show P xx, with "xx"
P 24
representing the currently set number of
Setting Economy mode:
daily purge cycles.
3- Use Up and Down arrows to change setting.
1- Press Econo key.
4- Press Filter key to store settings.
2- The display will show EDxx, with "xx"
ED12
representing the Economy mode duration.
3- Use Up or Down key to change setting.
4- Press Econo key again.
Boost filtration mode
5- The display will show ESxx, with "xx" representing
ES20
the delay before mode starts.
This function allows you to speed up filtration after intensive use of
6- Use Up and Down arrows to change setting.
your spa or to mix chemicals. Simply keep Pump 1 key pressed
7- Press Econo key a third time to store settings.
down for 5 seconds. Pump 1 will run at high speed for 45 minutes
and "BOO" message will be displayed. Ozonator is also activated.
40-minute Economy mode time-out: If you turn a pump, blower or
light on while Economy mode is on, the Economy mode will be
interrupted and will only resume 40 minutes after the system has
turned the last active output off. The "Econ" message or "Economy
"CLE" message
Mode" icon will flash, depending on your system configuration.
Every two weeks, the "CLE" message might be displayed indicating
to clean the filter (depending on your spa configuration). Press any
key to reset the message.
Inverted display
Press and hold Light key for 5 seconds to invert the display.
If a power-up occurs, the display always returns to default mode.
Real-time clock *
Use Clock key to set real-time clock. The display toggles every
5 seconds alternately showing the hourly time and the current
water temperature.
Summary of control panel parameters
Water level sensor
FDxx
Filter cycle duration
If the system is equipped with an optional water level sensor and the
FSxx
Filter cycle start delay
sensor detects an insufficient level of water in the tub, the system will
LocX
Control pad lockout
prevent pumps from starting and will display the "H20" message.
EDxx Economy mode duration
Pumps will be allowed to turn back on when water level returns
ESxx
Economy mode delay
above sensor.
P xx
Purge cycles
Smart
Winter
Mode
TM