CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
READING ERROR CODES
1. Turn knob to third position from the left.
2. Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time.
3. Immediately press and hold SELECT and CANCEL for six seconds. The control will enter Field Test Mode, the buzzer
will sound three times, and the digit display will alternate between "Fld" and the firmware revision number (ex. "r03").
4. Rotate the cycle selector knob two turns clockwise. The error code will appear in the digit display.
Troubleshoot problem by using chart below.
To move on to the next code, press the Options button.
To clear code, press the Select button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the Select and Cancel buttons for 6 seconds.
Error Code
Label
E10
General EEPROM
Fault
E11
Checksum Error
E12
Non fatal R/W
error
E24
Control NTC Short
Circuit
E25
Control NTC Open
Circuit
E4A
Program Timeout
Fault
E5B
Heater Fault (no
heating)
E68
Key (button) Struck
Fault
E8C
Too many trips in a
period of time.
EAF
Watch Dog Reset
NOTE: During normal operation, the display may show:
"LOC" - control lock is activated.
"PAU" - cycle has been interrupted.
Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
Description
Problem with communication
between EEPROM and the
microprocessor.
Problem with communications or
memory did not check, one has
become corrupted.
Problem reading or writing to the
memory or input/output.
Control thermistor or its wiring is
shorted.
Control thermistor or its wiring is
open.
The drying time has exceeded
program time for that cycle.
Temperature reading of control
thermistor has not changed in a
certain amount of time.
One of the keys (buttons) is stuck
closed (active).
The safety (high limit) thermostat
has tripped too many times within
a certain period of program time.
Microcontroller has been reset by
internal Watchdog timer.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Check for anything that would extend dry times such as:
no heat, restricted vent, blower fan blade broken or loose, dryer installed in
closet with solid door, or bad connection in moisture sensor bar circuit or
dirty bars. If dryer operates normally but code returns, replace electronic
control.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Measure voltage across terminals on relay RL2 (heater
relay) on electronic control. If meter reads 240V on electric models and
120V on gas models, replace electronic control. If meter reads zero, remove
power from dryer. Disconnect wire going to NO terminal on the relay RL2.
Reconnect power and measure voltage drop between terminal COM on
relay RL2 and neutral. If meter reads zero, wire between incoming line and
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.
Enter function test mode and perform key (button) test to determine which
button is at fault. Carefully free the and perform the test again. If button is
free but the key struck code still exists, replace electronic control.
Check for blocked lint filter, blocked exhaust, air leaks around air duct,
broken blower fan blades, worn or loose drum seals, dryer installed in closet
with solid doors or door seal not correctly seated.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
Solution
137312700A 1003

Advertisement

loading

Summary of Contents for Frigidaire FAQE7001LB

  • Page 1 Dryer Tech Data Sheet This information is intended for Qualified Technicians Only. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to its Envelope in the Product for Future Reference READING ERROR CODES 1. Turn knob to third position from the left. 2.
  • Page 2: Function Test Sequence

    FUNCTION TEST SEQUENCE 1. Turn knob to sixth position from the left. 2. Press and hold SELECT and CANCEL simultaneously for six seconds. The buzzer will sound one time. 3. Immediately press and hold OPTIONS and CANCEL simultaneously for two seconds. The control will enter test mode, the buzzer will sound three times and all LEDs will rapidly flash.
  • Page 3 Feuille de données techniques de sécheuse Ces renseignements ne s’adressent qu’à des techniciens qualifiés. ATTENTION : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT D’EFFECTUER TOUT ENTRETIEN Replacez cette feuille dans son enveloppe dans l’appareil pour référence ultérieure. AFFICHER LES CODES D'ERREUR 1. Tournez le bouton jusqu'à la troisième position à partir de la gauche. 2.
  • Page 4 NOTA : Durant le fonctionnement normal, les codes suivants peuvent s’afficher à l’écran: “LOC” - le verrou de commande est activé. “PAU” - le cycle a été interrompu. SÉQUENCE DU TEST DE FONCTION 1. Tournez le bouton jusqu'à la sixième position à partir de la gauche. 2.
  • Page 5 Hoja de Datos Técnicos de Secadora Esta información es Sólo para Técnicos Calificados. PRECAUCIÓN: DESCONECTE LA CORRIENTE ELÉCTRICA ANTES DEL SERVICIO Por favor, conserve esta hoja en su sobre en el producto para referencia futura LECTURA DE CÓDIGOS DE ERROR 1.
  • Page 6 NOTA: Durante la operación normal, se podrá ver lo siguiente en pantalla: “LOC” – el cierre de control está activado. “PAU” – el ciclo se ha interrumpido. SECUENCIA DE PRUEBA DE FUNCIÓN 1. Gire la perilla a la sexta posición desde la izquierda. 2.