PRESONUS DEQ624 User Manual

Digital stereo graphic equalizer plus dynamics processing
Hide thumbs Also See for DEQ624:

Advertisement

Quick Links

DEQ 624
Digital Stereo Graphic Equalizer
Plus Dynamics Processing
User' s Manual

Advertisement

Table of Contents
loading

Summary of Contents for PRESONUS DEQ624

  • Page 1 DEQ 624 Digital Stereo Graphic Equalizer Plus Dynamics Processing User’ s Manual...
  • Page 2 E Q U A L I Z E R P L U S D Y N A M I C S P R O C E S S O R USERS MANUAL Version 1.0 2001, PreSonus Audio Electronics, Incorporated. All rights reserved.
  • Page 4 PreSonus reserves the right to update any unit returned for repair. PreSonus reserves the right to change or improve the design of the product at any time without prior notice. This warranty does not cover claims for damage...
  • Page 5 The specific period of this limited warranty shall be that which is described to the original retail purchaser by the authorized PreSonus dealer or distributor at the time of purchase. PreSonus does not, however, warrant its products against any and all defects: 1)
  • Page 6: Table Of Contents

    TABLE OF CONTENTS Overview Introduction Features Controls & Connections Front Panel Basic Layout Operation Dynamics / Master Controls Meters Filters Expander Limiter Gain Bypass Range HI Q Enabling/Disabling HI Q Channel A Master Presets Storing/Recalling Presets Security Locking/Unlocking Front Panel Graphic Equalizer Back Panel Basic Layout Power Supply...
  • Page 7: Overview

    1 . 1 I N T R O D U C T I O N Thank you for purchasing the PreSonus DEQ 624 Digital Stereo Graphic Equalizer plus Dynamics Processor. This Digital Graphic Equalizer has been designed using advanced technology and state of the art components to deliver crystal clear audio for an infinite period of time.
  • Page 8: Features

    OVERVIEW 1 . 2 F E A T U R E S The following is a summary of your DEQ 624’ s features: 24-Bit Digital Signal Processing. The DEQ 624 utilizes 24-Bit resolution for accurate processing of analog signals. Dual 31 Band Equalizers. Each channel of the Graphic Equalizer section of the DEQ 624 is comprised of 31 digital EQ encoders.
  • Page 9 Entering a user-created three-switch code combination restores complete operation of the unit’ s front panel controls. AHC-Adaptive Hum Cancellation. This is a proprietary feature of the PreSonus DEQ 624. Annoying 50 Hz /60 Hz system hum caused by grounding problems can be greatly reduced without effecting program content by simply by engaging AHC.
  • Page 10: Controls & Connections

    CONTROLS & CONNECTIO NS 2 . 1 F R O N T P A N E L B A S I C L A Y O U T The front panel of the DEQ 624 is divided into two sections: Dual 31 Band Graphic Equalizers Dynamics / Master Control The Dynamics / Master control section of the DEQ 624 occupies the right side of the front...
  • Page 11: Dynamics / Master Controls

    CONTROLS & CONNECTIO NS D y n a m i c s / M a s t e r C o n t r o l Output Level Meter The output of each channel of the DEQ 624 can be monitored by way of dual twenty segment LED meters contained in the Dynamics / Master section.
  • Page 12: Filters

    CONTROLS & CONNECTIO NS Gain Reduction Meter The Gain Reduction Meters of the DEQ 624 monitor the activity of both the Expander and Limiter. These 10 segment LED meters are calibrated in increments from dB to dB and show the amount of Gain Reduction applied by the dynamics processors. The Gain Reduction meter continues measuring processor activity in Bypass mode.
  • Page 13: Expander

    CONTROLS & CONNECTIO NS selecting 20 kHz allows all frequencies from 20 kHz and below to pass through unaffected, effectively turning the Low Pass filter “Off”. Expander The DEQ 624 Expander is provided to eliminate system noise. The Expander is controlled by selecting a threshold point for downward expansion to begin and by selecting a ratio, which controls the amount of downward expansion.
  • Page 14: Gain

    CONTROLS & CONNECTIO NS T H R E S H O L D The Threshold control for the Limiter is calibrated from dBu to Off. Gain A Gain control on each channel of the DEQ 624 is the last controller in the signal path and is used to compensate for signal level loss from dynamics processing.
  • Page 15: Hi Q

    CONTROLS & CONNECTIO NS desired, it is probable that any EQ encoder choices made before the alteration in range will require resetting. Range selection for each channel is global and is applied to all channel EQ encoders. HI Q Normal Q (Q of the DEQ 624 is divided into bandwidths of 1/3 octave from 20 Hz to 20 kHz.
  • Page 16: Enabling/Disabling Hi Q

    CONTROLS & CONNECTIO NS The following example illustrates enabling and disabling HI Q for the 1kHz EQ encoder for Channel A. EXAMPLE Enabling HI Q for 1 kHz (Channel A) (HI Q is not enabled for any of Channel A’ s EQ encoders at the start of the sequence).
  • Page 17: Channel A Master

    CONTROLS & CONNECTIO NS Security switch light to go OFF. HI Q has now been de-selected for the Channel A 1 kHz EQ encoder. 4. Pressing the Channel A HI Q switch results in the Hi Q switch light going OFF and the unit to exit HI Q set-up mode.
  • Page 18: Ahc

    CONTROLS & CONNECTIO NS Channel B Channel B of the DEQ 624 is a duplicate of Channel A. All controls, encoders and LED indicators found on Channel A are found on Channel B. REMEMBER: When Channel Master A is engaged, all of Channel B’ s controls are disabled! Adaptive Hum Cancellation (AHC) Adaptive Hum Cancellation has been incorporated into the DEQ 624 for the express...
  • Page 19: Storing/Recalling Presets

    CONTROLS & CONNECTIO NS ON position). Press and release the Store / Security switch. Notice that the Store / Security switch and the Program 1 LED are blinking rapidly. You can cycle through all 4 Program positions and back to Manual mode by simply pressing and releasing the Store / Security switch.
  • Page 20: Locking/Unlocking Front Panel

    CONTROLS & CONNECTIO NS L O C K I N G T H E D E Q 6 2 4 To lock the DEQ 624, make sure the unit is in Preset mode. Now, while holding down the Store / Security switch; push any three switches in the Dynamics / Master control section.
  • Page 21: Graphic Equalizer

    CONTROLS & CONNECTIO NS 31 Digital Encoders per channel 6 dB (Red), 12 dB (Amber), 12 24 dB (Green) RANGE LED Indicators per channel 31 HI-Q Active LED indicators 2 . 4 B A C K P A N E L B A S I C L A Y O U T Both channels of the DEQ 624 XLR inputs and outputs, ¼”...
  • Page 22: Power Supply

    CONTROLS & CONNECTIO NS 2 . 7 P O W E R S U P P L Y The Power Supply for your DEQ 624 has been Factory Configured to use the voltage of the electrical current for the country of retail sale (USA = 115V). WARNING: Attempting to operate this unit at voltages for which this power supply was not designed will void the manufacturer’...
  • Page 23: Technical

    IEC receptacle Size 2U Rack Dimensions 19” X 9” X 3.5” Weight 14 lbs. Chassis Steel/Aluminum As a commitment to constant improvement, PreSonus, Inc. reserves the right to change any specification stated herein at any time in the future without notification.