Installation Requirements; Tools And Parts; Location Requirements - KitchenAid Architect Series II KDRS505XSS Installation Instructions Manual

30" (76.2 cm) double oven dual fuel ranges
Hide thumbs Also See for Architect Series II KDRS505XSS:
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure
Phillips screwdriver
T20 Torx
screwdriver
Flat-blade screwdriver
" flat-blade screwdriver
Level
Hand or electric drill
Wrench or pliers
Pipe wrench
" combination wrench
" (3.2 mm) drill bit
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block)
3 - Terminal lugs
LP/Natural Gas Conversion Kit (located on back of range near
lower side)
Burner grates
Burner caps
Oven racks
2 - #12 x 1 " screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with literature
package)
Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to
anchor bracket to subfloor. Longer screws are available from
your local hardware store.
Parts needed
If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1 " (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes and consult gas supplier. Check existing
electrical supply and gas supply. See "Electrical Requirements"
and "Gas Supply Requirements" sections.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
†®TORX is a registered trademark of Acument Intellectual Properties, LLC
4

INSTALLATION REQUIREMENTS

" nut driver
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection
solution
For LP/Natural Gas
Conversions
½" combination wrench
" (7.0 mm) nut driver
Masking tape

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located behind the control panel
and may be rotated up from behind the control panel for
viewing from the front of the range.
The range should be located for convenient use in the kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood or
microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.
Do not seal the range to the side cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Proper gas supply connection must be available. See "Gas
Supply Requirements" section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.