Make Gas Connection - KitchenAid Architect Series II KDRS505XSS Installation Instructions Manual

30" (76.2 cm) double oven dual fuel ranges
Hide thumbs Also See for Architect Series II KDRS505XSS:
Table of Contents

Advertisement

Available languages

Available languages

2. Attach terminal lugs (located in the package containing
literature) to line 1 (black), bare (green) ground, and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of the
terminal lug and insert exposed wire end through bottom of
terminal lugs. Securely tighten setscrew to
XX lbs-in. torque. See Bare Wire Torque Specifications chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
3. Use
" nut driver to connect the bare (green) ground terminal
lug to the center terminal block post with one of the 10-32 hex
nuts.
A
B
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
4. Connect line 1 (black) and line 2 (red) terminal lugs to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
16
A
B
E
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
F
E
D
C
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the other
adapter to the gas shutoff valve. Tighten both adapters.
3. Use a
" combination wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
H
G
F
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male
pipe thread)
D. Flexible connector
A
B
C
D
E
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter

Advertisement

Table of Contents
loading

Table of Contents