COMBUSTION AIR SYSTEM
4" VRV
4" IAH HOOD
This product is designed for use on the following burners, for the purpose of routing
combustion air directly to the burner, with the added safety feature of the vacuum relief valve.
NOTE: For burner inputs up to 2.0 GPH at 100 PSI input pressure or equivalent.
This device MUST be installed by a qualified agency* in accordance with the manufacturer's
installation instructions.
The definition of a qualified agency is: any individual, firm, corporation or company which
either in person or through a representative is engaged in, and is responsible for, the
installation and operation of oil appliances, who is experienced in such work, familiar with all
the precautions required, and has complied with all the requirements of the authority having
jurisdiction.
"The Air Boot™ models CAS-2B, CAS-2C and CAS-2W are for use only on the designated
burner(s) as described in these instructions only when the specific burner includes this Air
Boot™ when shipped from the burner manufacturer or where the burner instructions
specifically reference the models CAS-2B, CAS-2C or CAS-2W Air Boot™ as an optional air
intake system."
NOTE: This product brings combustion air only to the burner; must have adequate venting air
in accordance with NFPA-31.
Model: CAS-2B, 2C & 2W
I
TEMS INCLUDED IN KIT
1 - Air Boot™
1 - Set of Gaskets
1 - 4" VRV
1 - 4" IAH Hood
1 - Burner Coupling Set
2 - Mounting Bolts
1 - Flow Restrictor Pan (CAS-2B ONLY)
CAS-2B
BECKETT-AF/AFG
CAS-2C
CARLIN-EZ-1/CRD/FRD
CAS-2W
WAYNE-MSR
2630 Airport Road · Kinston, NC 28504
Phone: 252-522-3031· Fax: 252-522-0214
:
I
NSTALLER SUPPLIED ITEMS
Duct Piping and Elbows
90° Elbows;
¼ " NPT Female x ¼" NPT
Male for routing oil line
www.fieldcontrols.com
AIR BOOT™
: