Download Print this page

Dimplex Calidou CAL075 Installation And Operating Instructions

Dimplex operating instructions electronic panel radiator cal075, cal100, cal150, cal200

Advertisement

Calidou Electronic Panel Radiator
:
Models
CAL075 / CAL100 / CAL150 / CAL200
Dimensions and Specification
Model
Loading
Length (A)
(kW)
(mm)
CAL075
0.75
455
CAL100
1.0
621
CAL150
1.5
870
CAL200
2.0
1202
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electrical shock, and injury to
persons, including the following:
WARNING THE SURFACES OF THIS HEATER CAN BE HOT
Momentary contact with any part of the heater should not cause
injury. However, aged or infirm persons or young children should not
be left unsupervised in the vicinity of the heater unless a suitable
guard is fitted
IMPORTANT – If this heater is installed in a room containing a bath or
shower, it should be so installed that switches and other controls
cannot be touched by a person using a bath or shower – to comply
with this requirement see 'Lock the Control Cover' section on page 2.
If you use this heater in conjunction with an external thermal control,
a programme controller, a timer or any other device which switches
the heat on automatically, observe all safety warnings AT ALL TIMES
since a fire risk exists when the heater is accidentally covered or
displaced
The installation of this product should be carried out by an electrician
or competent person and be in strict accordance with the current IEE
Wiring Regulations and relevant Building Regulations
This heater must not be mounted within 150mm of curtains and other
combustible materials or 100mm from a shelf or overhang
NEVER cover or obstruct in any way the heat outlet slots at the top of
the heater or the air inlet slots at the base of the heater
DO NOT cover the heater – Do not place material or garments on the
heater or obstruct the air circulation around the heater
Before connecting the heater check that the supply voltage is the
same as that stated on the heater
The heater must be installed in accordance with these instructions
The heater must be mounted using the wall bracket supplied. The
heater should only be operated in the upright position
The heater should be positioned in accordance to the clearances
stated in these instructions
DO NOT locate this heater immediately beneath a fixed socket outlet
Electrical
The wires in the mains lead are coloured in accordance with the following code:
GREEN & YELLOW
EARTH
BLUE
NEUTRAL
BROWN
LIVE
BLACK
PILOT WIRE
(See also 'Pilot Wire Connection')
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the
premises through a suitable connection box positioned adjacent to the heater.
The supply circuit to each heater must incorporate a double pole isolating switch having a
contact separation of at least 3mm
Pilot Wire Connection
The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex
programmers. If, however a programmer is not being used, the pilot wire should be isolated in
accordance with the current IEE Wiring Regulations.
IMPORTANT - Do NOT connect the BLACK pilot wire to earth
Care should be taken with the installation of the pilot wire(s) as when switching to background
(set back) they become energised at 240V although only at a current of 1mA.
In every case a suitable means of isolation must be provided for the pilot wire and marked to
indicate that two sources of supply may be present at the heater.
Where pilot wires are installed separately from the heater final sub-circuit they should be
protected, double insulated and carry their own integral earth continuity conductor.
Height
Depth
X
Y
(mm)
(mm)
(mm)
(mm)
604
142
140
87
604
142
300
87
604
142
400
226
604
142
700
227

Installation and Operating Instructions

Z
Weight
(mm)
(kg)
228
17
234
24
242
33
275
47
General
The Calidou radiator is designed to provide exceptional levels
of comfort with a combination of radiant and convected heat
in both domestic and commercial applications.
Wall Mounting / Installation
The heater should be positioned observing the minimum clearances
stated around the heater.
(see also 'Electrical' section)
The wall bracket supplied with the heater must be used
1. Using a screwdriver, turn the latch in a clockwise direction to
unlatch the bracket, then remove it from the appliance (see Fig.1)
2. Mount the bracket on the wall using a minimum of 4 screws
(max diameter 6mm) making sure that it is the correct way up and
at the correct height. (see Fig.2)
3. Position the appliance on the bracket.
4. Re-latch the bracket turning the latch anti-clockwise.
Model
A (mm
CAL075
140
CAL100
300
CAL150
400
CAL200
700
If the wall is a light partition or crumbling, then supporting legs
are also needed
(Part No. CAL0001). The heater MUST be fitted to the wall as
well as having the supporting legs
1.
Place the legs under the heater
2.
Position the hinges into the grooves in the air inlet
3.
Unscrew the jacks, until they reach the floor
IP24
Issue 5 November 2004
Fig.1
Fig. 2
B (mm)
228
234
242
27

Advertisement

loading

Summary of Contents for Dimplex Calidou CAL075

  • Page 1: Installation And Operating Instructions

    3mm Pilot Wire Connection The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex programmers. If, however a programmer is not being used, the pilot wire should be isolated in accordance with the current IEE Wiring Regulations.
  • Page 2: Mode Selection Dial

    Note: If the programme function is selected but no programming device is being used, the heater will function in comfort mode The following Dimplex programmers are available Pilot Wire Wall Mounted Controller (2 Zone) – Part no. RX010006 MBS Wall Mounted Programmer (2 Zone) – Part no. RX010007 MBS Slot in Receiving Cassette –...

This manual is also suitable for:

Calidou cal100Calidou cal150Calidou cal200