Symptom
No function after
switching on
No playback,
pre-amplifier display
is functional
One channel play
back only
Remote commands
have no effect
Low frequency hum-
ming noise audible

TROUBLESHOOTING

Possible reason
Power cable not connected to an active
wall outlet
Power cable not connected tight to
wall outlet or chassis jack
Power cable defective
Blown Fuse
Volume setting too low
Not the desired input channel has been chosen
You did not (or not correctly) connect the
output of the source device oder not to the
desired input connector of the pre-amplifier
Source device does not give output signal
You did not (or not correctly) connect
the main amplifier, or switched it off
Speaker cable connections to the main
amplifier are not correct or speakercable
damaged
One of the speaker cables has not or not
correctly been connected, or defective
speaker cable
One of the signal cables between pre-
amplifier and main amplifier has not or not
correctly been connected, or defective signal cable
One of the signal cables between Source and
pre-amplifier has not or not correctly been
connected, or defective signal cable
The balance setting is extreme
No batteries or used-up cells in the remote set
Line of sight between remote set and audio
device is blocked or maximum distance is
exceeded or commands given from a too
large angle
Device switched off
See previous page
Possible solution
Connect the power cable to an active
wall outlet
Press the power plugs tight into the wall
outlet and the device's power connector
Change against an adequate power cable
Change fuse
Carefully increase the volume
Revise your selection
Check and correct the connections
Start the playback of the source device
Check connections and function of the
main amplifier
Check and revise speaker cables and their
connections
Check speaker cables and their connections
on both sides
Check signal cables and their connections on
both sides
Check signal cables and their connections on
both sides
Correct this setting
Check and replace battery cells if necessary
Try and use remote set only at free line of
sight inside the radius of maximum distance
facing the front panel
Device switched on