Desa CTR22PR Safety Information And Installation Manual

Desa safety information and installation manual unvented (vent-free) infrared gas heater ctr25nr, ctr22pr, vtn25r and vtp22r
Table of Contents

Advertisement

Available languages

Available languages

UNVENTED (VENT-FREE) INFRARED GAS HEATER
SAFETY INFORMATION AND INSTALLATION MANUAL
MODELS CTR25NR, CTR22PR, VTN25R AND VTP22R
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
For more information, visit www.desatech.com
Save this manual for future reference.

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Desa CTR22PR

  • Page 1 UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL MODELS CTR25NR, CTR22PR, VTN25R AND VTP22R WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This is an unvented gas-fired heater.
  • Page 3: Safety Information

    SAFETY INFORMATION WARNING: This product con- tains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion,...
  • Page 4: Local Codes

    SAFETY INFORMATION Continued 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5.
  • Page 5: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construc- tion unless provisions are provid- ed for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 6: Combustion And Ventilation Air

    51,200 (maximum Btu/Hr the space can support) Add the Btu/Hr (kw) of all fuel burning appli- ances in the space. Vent-free heater ________ Btu/Hr (kw) Gas water heater* ________ Btu/Hr (kw) Gas furnace ________ Btu/Hr (kw) Vented gas heater ________ Btu/Hr (kw) Gas fireplace logs...
  • Page 7: Installation

    AIR FOR COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" (30.5 cm) of the ceiling and one within 12" (30.5 cm) of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 8 INSTALLATION Continued WARNING: Never install the heater • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing or other flammable objects are less than 36 inches (91.4 cm) from the front or top of the heater or less than 10" (25.4 cm) from sides of heater •...
  • Page 9 INSTALLATION Continued Figure 7 - Connecting Receiver Wire INSTALLING BATTERIES INTO REMOTE 1. Locate hand-held remote control in hardware bag included with your heater. 2. Remove battery cover and insert supplied batter- ies into remote control as shown in Figure 8. 3.
  • Page 10: Local Codes

    INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: For natural gas, never connect heater to private (non-utility) gas wells.
  • Page 11 INSTALLATION Continued Pressure Regulator Heater Cabinet Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT 3" Plug Tap (76 mm) Min. Pipe Joint Nipple [7" (1.8 kPa) WC to Sediment Trap 10.5" (2.6 kPa) WC From External Regulator [11" (2.7 kPa) WC to 14" (3.5 kPa) WC Pressure] Figure 13 - Gas Connection * A CSA design-certified equipment shutoff valve...
  • Page 12 INSTALLATION Continued Equipment Shutoff Valve Figure 14 - Equipment Shutoff Valve Meter Figure 15 - Checking Gas Joints for Propane/LP Supply Tank Figure 16 - Checking Gas Joints for Open Closed www.desatech.com Equipment Shutoff Valve Thermostat Gas Valve (Inside Heater) Natural Gas Propane/LP Gas 113261-01A...
  • Page 13: Operating Heater

    OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
  • Page 14 OPERATING HEATER Continued HAND-HELD REMOTE CONTROL OPERATION 1. Slide selector switch on remote receiver to the REMOTE position. 2. Slightly pull and turn auxiliary knob so the AUX is to the left and right and ON is to the top and bottom positions. 3.
  • Page 15 Blue Flame Pilot Burner Thermocouple Yellow Flame Pilot Burner Thermocouple 113261-01A www.desatech.com...
  • Page 16: Cleaning And Maintenance

    If so, contact DESA Heating Productsʼ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA Heating Productsʼ techni- cal service web site at www.desatech.com. www.desatech.com Pilot Assembly...
  • Page 17: Troubleshooting

    WARNING: Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed in, there is no spark at ODS/...
  • Page 18 OBSERVED PROBLEM ODS/pilot lights but flame goes out when control knob is released Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during com- bustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/tick- ing noise just after burner is lit...
  • Page 19 WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 20: Illustrated Parts Breakdown

    ILLUSTRATED PARTS BREAKDOWN MODELS CTR25NR, VTN25R, CTR22PR AND VTP22R www.desatech.com 113261-01A...
  • Page 21: Parts List

    114021-01 114021-02 113172-01 099415-21 114250-01 098264-02 114012-01 114031-01 113262-01 113264-01 113264-02 105345-01 ** Not a field replaceable part. 113261-01A PARTS LIST CTR22PR VTP22R DESCRIPTION 113079-01 Grill Wrapper 114659-01 Grill Screws 114032-01 Receiver Remote M50104-06 Bushing 114254-01 Top Burner Assembly 114254-02...
  • Page 22: Specifications

    If they can not supply these accessories, either contact your nearest Parts Central (see page 23) or call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
  • Page 23: Parts Central

    These Parts Centrals are privately owned businesses. They have agreed to support our customerʼs needs by providing original replacement parts and accessories. Tools & Equipment Co. 5 Manila Ave Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 219-462-7441 1-888-619-7060...
  • Page 24 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com Patent Pending...
  • Page 25 CALENTADOR DE GAS INFRARROJO NO VENTILADO INFORMACIÓN DE SEGURIDAD Y MANUAL DE INSTALACIÓN MODELOS CTR25NR, CTR22PR, VTN25R Y VTP22R ADVERTENCIA: Si la información contenida en este manual no se sigue al pie de la letra, se puede producir un incendio o una explosión que podría ocasionar daños a la propiedad,...
  • Page 26 ADVERTENCIA: La instalación, ajuste, alteración, servicio o mantenimiento inadecuados pueden provocar lesiones o da- ños a la propiedad. Consulte este manual para conocer los pro- cedimientos correctos de instalación y operación. Para obtener asistencia o información adicional consulte a un instalador capacitado, agencia de servicio o al proveedor de gas.
  • Page 27: Información De Seguridad

    INFORMACIÓN DE SEGURIDAD Continuación PELIGRO: La intoxicación con monóxido de carbono puede resultar en la muerte! Intoxicación con monóxido de carbono: iniciales de la intoxicación con monóxido de carbono son semejantes a los de la gripe, con dolores de cabeza, mareos y/o náusea.
  • Page 28: Códigos Locales

    6. Mantenga limpias y libres de residuos todas las aberturas de las partes anterior e inferior del ca- lentador. Esto asegurará que haya suficiente aire para lograr una combustión adecuada. 7. Si el calentador se apaga, no lo vuelva a encender hasta que éste cuente con aire fresco del exterior.
  • Page 29: Aire Para Combustióny Ventilación

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN ADVERTENCIA: Este calentador no debe instalarse en un espacio con- finado o en una construcción inusual- mente sellada a menos que se hayan tomado medidas para proporcionar el aire adecuado para combustión y ventilación. Lea las instrucciones a continuación para asegurarse de que su hogar cuente con la cantidad ade- cuada de aire fresco para éste y otros...
  • Page 30 AIRE PARA COMBUSTIÓN Y VENTILACIÓN Continuación Determine el volumen del espacio (largo x ancho x altura). Largo x ancho x altura =__________ m (volumen del espacio) Ejemplo: tamaño del espacio, largo: 20 pies (6,1 m); x ancho: 16 pies (4,88 m); x altura del techo: 8 pies (2,44 m) = 2560 pies cúbicos (72,49 m del espacio) Si se proporciona ventilación adicional a los cuartos...
  • Page 31: Instalación

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN Continuación Aire del exterior para ventilación Procure aire fresco adicional mediante el uso de rejillas o conductos de ventilación. Debe proporcionar dos aberturas permanentes: una a 30,48 cm (12 pulgadas) o menos del techo y otra a 30,48 cm (12 pulgadas) o menos del suelo.
  • Page 32 INSTALACIÓN Continuación ADVERTENCIA: Nunca instale el calentador • en una recámara o baño • en un vehículo recreativo • donde cortinas, muebles, ropa u otros objetos inflamables estén a menos de 91,4 cm (36 pulgadas) de las partes anterior o superior del calentador o a menos de 25,4 cm (10 pulgadas) de las partes laterales del calentador...
  • Page 33 Figura 7. Conexión del alambre del receptor INSTALACIÓN DE LAS BATERÍAS EN EL CONTROL REMOTO 1. Sitúe el control remoto portátil en la bolsa de hardware incluida con su calentador. 2. Retire la cubierta de la batería e inserte las baterías proporcionadas en el control remoto como se muestra en la figura 8.
  • Page 34 CONEXIÓN AL SUMINISTRO DE GAS ADVERTENCIA: Este aparato requiere una conexión de entra- da tipo NPT (Rosca de tubería nacional) de 3/8 de pulgada al regulador de presión. ADVERTENCIA: Una persona de servicio capacitada debe co- nectar el calentador al suministro de gas.
  • Page 35 Regulador de presión Gabinete del calentador Unión T Buje reductor a 1/8 de pulgada tipo Rosca interna tipo 76 mm NPT de 1/8 (3") Min. de pulgada con tapón Unión Boquilla Tapón de tubería Trampa de sedimentos Figura 13. Conexión de gas * Una válvula de cierre de equipo certificada con diseño CSA con rosca interna tipo NPT de 1/8 de pulgada es una alternativa aceptable para probar la...
  • Page 36 Válvula de cierre de equipo Figura 14. Válvula de cierre del equipo Medidor de gas Figura 15. Revisión de las uniones de Tanque de suministro de propano o gas LP Figura 16. Revisión de las uniones de gas para propano o gas LP Abierta Cerrada www.desatech.com...
  • Page 37: Funcionamiento Del Calentador

    FUNCIONAMIENTO DEL CALENTADOR PARA SU SEGURIDAD, LEA ESTO ANTES DE ENCENDERLO ADVERTENCIA: Si no sigue es- tas instrucciones exactamente, se puede producir un incendio o una explosión que ocasione daños a la propiedad, lesiones personales o pérdida de la vida. A.
  • Page 38 FUNCIONAMIENTO DEL CALENTADOR Continuación FUNCIONAMIENTO DEL CONTROL REMOTO 1. Deslice el interruptor de selección del control remoto a la posición REMOTE (CONTROL REMOTO). 2. Jale y gire ligeramente la perilla auxiliar de manera que AUX esté en las posiciones izquierda y derecha y ON (ENCENDER) esté en las posiciones superior e inferior.
  • Page 39 113261-01A Termopar Termopar www.desatech.com Llama azul Quemador del piloto Llama amarilla Quemador del piloto...
  • Page 40: Limpieza Ymantenimiento

    De ser así, póngase en contacto con el depar- tamento de servicio técnico de DESA Heating Products al teléfono 1-866-672-6040. Al llamar tenga a la mano los números de modelo y serie de su calentador.
  • Page 41: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS ADVERTENCIA: Apague y desconecte el calentador y deje que se enfríe antes de darle servicio. Sólo una persona de servicio capacitada debe reparar el calentador o darle servicio. PRECAUCIÓN: Nunca utilice un alambre, aguja u objetos parecidos para limpiar el piloto/ODS.
  • Page 42 SOLUCIÓN DE PROBLEMAS PROBLEMA OBSERVADO El piloto con ODS se enciende pero la llama se extingue cuando se suelta la perilla de control El (los) quemador(es) no se enciende(n) después de que el pi- loto con ODS está encendido Hay un retraso en el encendido de los quemadores El quemador muestra llamas de retorno durante la combustión...
  • Page 43 SOLUCIÓN DE PROBLEMAS ADVERTENCIA: Si percibe olor a gas • Cierre el suministro de gas. • No intente encender ningún aparato. • No toque ningún interruptor eléctrico; no use ningún teléfono en el edificio. • Llame inmediatamente a su proveedor de gas desde el teléfono de algún vecino.
  • Page 44 CLASIFICACIÓN ILUSTRADA DE PIEZAS MODELOS CTR25NR, VTN25R, CTR22PR Y VTP22R www.desatech.com 113261-01A...
  • Page 45 114250-01 098264-02 114012-01 114031-01 113262-01 113264-01 113264-02 105345-01 ** No es una pieza que se pueda reemplazar en el sitio. 113261-01A LISTA DE PIEZAS CTR22PR VTP22R DESCRIPCIÓN 113079-01 Parrilla Cornamusa 114659-01 Tornillos de la parrilla 114032-01 Receptor remoto M50104-06 Buje...
  • Page 46: Especificaciones

    12,7 kg (28 lbs) 15 kg (33 lbs) PUBLICACIONES PARA Puede adquirir un manual de servicio en la direc- ción que se lista al reverso de este manual. Envíe un cheque por $5,00 dólares a nombre de DESA Heating Products. www.desatech.com CTR22PR VTP22PR 22,000 (6,4) Sólo propano o gas LP...
  • Page 47: Piezas De Repuesto

    Póngase en contacto con distribuidores autorizados de este producto. Si no pueden proporcionarle las piezas de repuesto originales, llame al departamen- to de servicio técnico de DESA Heating Products al 1-866-672-6040. Cuando llame a DESA Heating Products, tenga listo: • su nombre •...
  • Page 48 Patente en trámite 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004, USA EE.UU. www.desatech.com 113261 01 NOT A UPC 113261-01 Rev. A 07/04...

This manual is also suitable for:

Ctr25nrVtn25rVtp22r

Table of Contents