Download Print this page
BENDIX CYCLONE DURADRAIN TRAILER WATER Instructions

BENDIX CYCLONE DURADRAIN TRAILER WATER Instructions

Trailer water separator

Advertisement

Quick Links

®
Bendix
Cyclone DuraDrain
DELIVERY PORT
"OUT"
PURGE NUT WITH
DRAIN
FIGURE 1 - CYCLONE DURADRAIN
DESCRIPTION
The Cyclone DuraDrain
installed in the trailer control or in the supply line near the
gladhand. It removes water and contaminants that can
cause brakes to drag and improves the life of the trailer
system components.
OPERATION (See Figure 1)
Compressed air enters the supply port of the Cyclone
DuraDrain
trailer water separator. The air pressure pushes
down on the check valve contained in the purge nut and
closes the purge nut drain port. When air enters the supply
port of the Cyclone DuraDrain
cyclonic action is created.
The cyclonic motion separates the oil, water and particulates.
The oil, water and particulates gravitate to the bottom of the
Cyclone DuraDrain
trailer water separator where they
collect. When the air pressure above the purge nut check
valve returns to atmospheric pressure, the check valve moves
up and off its seat. The contaminants then drain through
the purge nut drain port.
Trailer Water Separator
.28 DIA.
MOUNTING
HOLES
SUPPLY PORT
"IN"
TRAILER WATER SEPARATOR
trailer water separator can be
trailer water separator a
DELIVERY PORT
"OUT"
SCREENS
PURGE NUT WITH
CHECK VALVE
If water from a gladhand enters the supply port and no air
pressure is applied, gravity will allow the water and
contaminants to drain through the purge nut drain port.
GENERAL SAFETY GUIDELINES
WARNING! PLEASE READ AND FOLLOW
THESE
INSTRUCTIONS
PERSONAL INJURY OR DEATH:
When working on or around a vehicle, the following
general precautions should be observed at all times.
1. Park the vehicle on a level surface, apply the
parking brakes, and always block the wheels.
Always wear safety glasses.
2. Stop the engine and remove ignition key when
working under or around the vehicle. When
working in the engine compartment, the engine
should be shut off and the ignition key should be
removed. Where circumstances require that the
engine be in operation, EXTREME CAUTION should
be used to prevent personal injury resulting from
contact with moving, rotating, leaking, heated or
electrically charged components.
SUPPLY PORT
"IN"
O-RING
DRAIN
TO
AVOID
1

Advertisement

loading

Summary of Contents for BENDIX CYCLONE DURADRAIN TRAILER WATER

  • Page 1 ® ™ Bendix Cyclone DuraDrain Trailer Water Separator DELIVERY PORT .28 DIA. DELIVERY PORT “OUT” MOUNTING “OUT” HOLES SUPPLY PORT “IN” SCREENS SUPPLY PORT “IN” O-RING PURGE NUT WITH DRAIN PURGE NUT WITH DRAIN CHECK VALVE ™ FIGURE 1 - CYCLONE DURADRAIN...
  • Page 2 1. Disconnect the supply and delivery line fittings. system pressure has been depleted. 2. Remove the mounting hardware, and spacer if applicable, 8. Use only genuine Bendix ® replacement parts, ™ that secures the Cyclone DuraDrain trailer water components and kits.
  • Page 3 SPRING BRAKE ™ CYCLONE DURADRAIN TRAILER WATER SEPARATOR CONTROL ABS UNIT OR SUPPLY RELAY VALVE PLACEMENT OF OPTIONAL ™ SR-5 SPRING SUPPLY LINE CYCLONE BRAKE VALVE DURADRAIN ™ TRAILER WATER SEPARATOR FIGURE 3 - TRAILER SCHEMATIC SERVICE INTERVALS 2. When full system pressure is reached, and the spring brakes are fully released, apply a soap solution to the Service intervals are dependent on specific environmental ™...
  • Page 4 10. Reapply air pressure and determine if the leak has been eliminated. 11. If the air leak persists, replace the entire purge nut with Bendix service kit piece number 5013824. BW2440 © 2006 Bendix Commercial Vehicle Systems LLC. All rights reserved. 7/2006 Printed in U.S.A.

This manual is also suitable for:

Cyclone duradrain