JRC SAW FILTER
Application
314.35MHz R.K.E.
Electrical Specification: (Table 1)
The device characteristics are measured in the circuit shown in Fig.1.
Table 1. Electrical Specifications
Item
Input and Output Impedance
Nominal Center Frequency (f0)
Insertion Loss
Response Variation
Input and Output VSWR
Out of Band Rejection
(Relative to Through Level)
Maximum Rating: (Table 2)
Table 2. Maximum Ratings
Item
Maximum Input Power
Maximum DC Voltage
Operating Temperature Range
Storage Temperature
Mechanical Specifications: (Fig.2)
Package is designed as small as 3.5x3.5x1.0[mm
Notice:
This part is electrostatic discharge sensitive and may be damaged by improper handling.
Communications Equipment Marketing Department
http://www.jrc.co.jp/jp/product/device/saw/index.html (Japanese)
http://www.jrc.co.jp/eng/product/saw/index.html(English)
NSVS681
313.85~314.85MHz
313.85~314.85MHz
313.85~314.85MHz
292.95MHz
335.75MHz
(Operating Temperature Range: -20~+70ºC)
Rating
+20dBm
7.5V
-20~+70ºC
-30~+80ºC
Communications Equipment Division
10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku,
Tokyo, 160-8328 Japan
Tel. +81 3-3348-3845
Fax. +81 3-3348-3935
NSVS681 Jan. 2005
Spec.
50Ω
314.35MHz
3.0dB max.
1.5dB max.
2.5 max.
50dB min.
45dB min.
3
] for SMD (Surface Mount Device) type.
Typ.
-
-
1.8dB
0.6dB
1.5
67dB
51dB

Advertisement

loading

Summary of Contents for JRC NSVS681

  • Page 1 NSVS681 Jan. 2005 JRC SAW FILTER NSVS681 Application 314.35MHz R.K.E. Electrical Specification: (Table 1) The device characteristics are measured in the circuit shown in Fig.1. Table 1. Electrical Specifications Item Spec. Typ. Input and Output Impedance 50Ω Nominal Center Frequency (f0) 314.35MHz...
  • Page 2 NSVS681 Jan. 2005 50Ω 50Ω Fig.1 Measuring circuit 3.5±0.2 Marking (1) Manufacture’s Mark (2) Lot Number (a) Year (b) Month (0.95) (0.8) *Oct.--- X [5x] Nov.--- Y Dec.--- Z (3) Part number Mark (0.6) Pin no. Connection IN/OUT OUT/IN Fig.2 Package dimensions (in mm) [6x] Φ...
  • Page 3 NSVS681 Jan. 2005 Notice 1. Use this component within operating temperature range. It might not be satisfied with electrical specification without operating temperature range. When it is used less than -20ºC or more than +70ºC, it might be a cause of degradation or destruction of the component.
  • Page 4 NSVS681 Jan. 2005 ‚ ‚ ‚ 50 O *27nH ‚ U 39pF 50 O *27nH ‚ T ‚ ‚ ‚ ‚ 33pF FREQUENCY CHARACTERISTICS *murata LQW18A series Fig.1 Measuring circuit 13.30±0.20 (1.26±0.13) J4Y1 VS971 CH1 : center 314.35 span 100 CH2 : center 314.35 span 100...