UNVENTED (VENT-FREE) GAS FIREPLACE
OWNER'S OPERATION AND INSTALLATION MANUAL
Shown with optional cabinet mantel, hearth base, and trim accessories.
THERMOSTATICALLY-CONTROLLED MODELS
VSGF28NTE AND VSGF28PTE WITH SPLIT OAK LOGS
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
For more information, visit www.desatech.com
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQQQQQ
QQQQQQ
QQQQQQQQQQ
QQQQQQ
QQQQQQQQQQ
Save this manual for future reference.
®
QQQ
QQQ
QQQ

Advertisement

Table of Contents
loading

Summary of Contents for Desa Vanguard VSGF28NTE

  • Page 1 QQQQQQQQQQ Shown with optional cabinet mantel, hearth base, and trim accessories. THERMOSTATICALLY-CONTROLLED MODELS VSGF28NTE AND VSGF28PTE WITH SPLIT OAK LOGS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency, or the gas supplier. WARNING: This is an unvented gas-fired heater.
  • Page 3: Safety Information

    SAFETY INFORMATION WARNING: This product con- tains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosion, elec-...
  • Page 4: Local Codes

    SAFETY INFORMATION Continued 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone.
  • Page 5: Unpacking

    PRODUCT IDENTIFICATION Middle Log Rear Burner Front Front Burner Figure 1 - Log Base Assembly, Split Oak Set Top Louver Assembly Fireplace Hood Firebox Support Screen Assembly Bottom Louver Assembly Figure 2 - Fireplace UNPACKING CAUTION: Do not remove the data plates attached to the heater base assembly.
  • Page 6: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 7 AIR FOR COMBUSTION AND VENTILATION Continued If additional ventilation to adjoining room is sup- plied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
  • Page 8: Installation

    AIR FOR COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 9 INSTALLATION Continued IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fire- place in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 6 through 8.
  • Page 10: Installation Clearances

    INSTALLATION Continued INSTALLATION CLEARANCES WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. Carefully follow the instructions below. This will ensure safe installation. Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A.
  • Page 11 INSTALLATION Continued 9. If blower is installed, route blower electrical cord through access holes in either side of fire- place. Note: Bushing may be moved if neces- sary. Plug electrical cord into electrical outlet. 10. Carefully insert fireplace into cabinet mantel (Figure 12).
  • Page 12 INSTALLATION Continued 2. If using blower, install and properly ground GA3555, three-prong 120 volt electrical outlet, in fireplace. Follow instructions included in kit. 3. Install gas piping into fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve.
  • Page 13 INSTALLATION Continued Installation Items Needed Before installing fireplace, make sure you have the items listed below. • external regulator (supplied by installer) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * •...
  • Page 14 INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • 5/16" hex socket wrench or nut-driver • Phillips screwdriver • sealant (resistant to propane/LP gas, not pro- vided) 1. Remove fireplace screen. Remove two screws that hold fireplace screen in place for ship- ping.
  • Page 15: Checking Gas Connections

    INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak de- tection fluid to all joints.
  • Page 16 INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These num- bers will help you identify the log when install- ing.
  • Page 17: Operating Fireplace

    OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
  • Page 18 OPERATING FIREPLACE Continued 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.
  • Page 19: Inspecting Burners

    INSPECTING BURNERS Check pilot flame pattern and burner flame pat- terns often. PILOT FLAME PATTERN Figure 30 shows a correct pilot flame pattern. Fig- ure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermo- couple.
  • Page 20: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of fire- place clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person.
  • Page 21: Troubleshooting

    Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
  • Page 22 OBSERVED PROBLEM ODS/pilot lights but flame goes out when control knob is re- leased One or both burners do not light after ODS/pilot is lit Delayed ignition of one or both burners Burner backfiring during com- bustion Yellow flame in front burner during burner combustion Slight smoke or odor during ini- tial operation...
  • Page 23 OBSERVED PROBLEM Fireplace produces a whistling noise when burners are lit White powder residue forming within burner box or on adja- cent walls or furniture Dark residue on logs or inside of fireplace Note: After removing all causes of residue deposits, completely clean fireplace and appliance of all residue before reusing appliance...
  • Page 24 WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 25: Specifications

    If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ tech- nical services web site at www.desatech.com VSGF28PTE...
  • Page 26: Illustrated Parts Breakdown And Parts List

    ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY MODELS VSGF28NTE AND VSGF28PTE www.desatech.com 113135-01A...
  • Page 27: Parts List

    LOG BASE ASSEMBLY This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. PART NUMBER VSGF28NTE 110881-01 110881-02 110881-03 M11084-38 098304-01 104285-01 098249-01 101006-02 101330-05...
  • Page 28 ILLUSTRATED PARTS BREAKDOWN FIREPLACE MODELS VSGF28NTE AND VSGF28PTE www.desatech.com 113135-01A...
  • Page 29 FIREPLACE MODELS VSGF28NTE AND VSGF28PTE This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. PART NUMBER 101357-01 102758-02CK 102759-02CK 098304-01 101351-01CK 102455-18 101353-01CK 101712-02...
  • Page 30: Accessories

    Purchase these fireplace accessories from your local dealer. If they can not supply these accesso- ries, call DESA Heating Products’ Sales Depart- ment at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.
  • Page 31 ACCESSORIES Continued HARDWOOD HEARTH BASE GC3333F Series- Walnut Finished GC3334U Series - Unfinished GC3335F Series - Oak Finished with Medium Stain G3004W Series - Off-White Paint The hearth base can be used with the cabinet man- tels to create a handsome riser for the fireplace (cannot be used with corner mantel).
  • Page 32: Warranty Information

    This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Autho- rized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts.