Installation Instructions - STEINEL IS 3180 Manual

Infrared sensor
Hide thumbs Also See for IS 3180:

Advertisement

Installation instructions

GB
Dear Customer,
Congratulations on purchasing your new
STEINEL infrared sensor and thank you for the
confidence you have shown in us. You have
chosen a high-quality product that has been
manufactured, tested and packed with the
greatest care.
Please familiarise yourself with these instruc-
Principle
The unit is equipped with pyro sensors that
detect the invisible heat emitted from moving
objects (people, animals etc.). The heat detect-
ed in this way is electronically converted into
a signal that switches on connected loads
Installation
The site of installation should be at least 50 cm
away from another light because heat radiated
from it may activate the system.
An optional corner wall mount (product no.
648015 black or 648114 white) is available for
installing the sensor on internal and external
corners.
The mains lead consists of a 3 phase cable.
L
= Phase
N = Neutral conductor
PE = Protective-earth conductor
Safety warnings
Disconnect the power supply before at-
tempting any work on the sensor!
The electrical connection lead must be
dead during installation. Therefore, switch
off the power first and use a voltage tester
to make sure the wiring is off circuit.
tions before attempting to install the sensor
because prolonged reliable and trouble-free
operation will only be ensured if it is fitted
properly.
We hope your new infrared sensor brings you
lasting pleasure.
(e.g. a light). The built-in red LED also lights up.
The sensor does not detect heat radiated from
behind obstacles, such as walls or panes of
glass. Heat radiation of this type will therefore
not activate a light.
If the rubber seal is damaged, the cable entry
openings must be sealed with an M 16 or M 20
(at least IP 54) double seal cable gland.
A condensation hole is indicated next to the
rubber seal. This must be opened if necessary.
Installing the sensor involves work on the
mains power supply. This work must there-
fore be carried out professionally in accord-
ance with applicable national wiring regula-
tions and electrical operating conditions.
(
-VDE 0100,
-ÖVE-EN 1,
-SEV 1000)
Only select time and twilight setting with the
lens in place.
14
System components
IS 3180, IS 3360, IS 345
Standard installation
Installation in ceiling box
Basic element
Concealed wiring
Surface wiring
Plug-in terminals
Fitting the sensor cover
Fitting the shrouds
Screwing on the lens
Twilight setting (2 – 2000 lux)
Time setting (5 sec. – 15 min.)
Reaches for IS 3180
Mounting
20 m lens
height
Setting level
tangentially
1.5 m
8
5 m
6 m
7 m
8 m
20
12 m
2.0 m
8
5 m
6 m
7 m
10 m
20
20 m
2.5 m
8
6 m
8 m
10 m
13 m
20
20 m
3.0 m
8
8 m
9 m
12 m
17 m
20
20 m
Connection examples
Lamp not fitted with a neutral conductor
Lamp fitted with a neutral conductor
Connection via two-circuit switch for
manual and automatic operation
Connection via a two-way switch for
21
manual override and automatic operation
Position I: automatic operation
Position II: manual operation
light ON permanently
Note: the system cannot be switched off,
but operated only at settings I and II.
a) Load, max. illumination 2000 W
(see Technical specifications)
Reset button for returning the twilight and
time setting to the factory setting of 2000
lux and 5 sec.
Fitting the decorative faceplate
Lens rotates for selecting basic settings:
8 m max. or 20 m max.
Lens slides for adjusting reach:
4 – 8 m or 8 – 20 m
IS 3180
Drainage hole for wall installation
(open if necessary)
Drainage hole for ceiling installation
(open with a 5 mm drill if necessary)
8 m lens
radially
Setting level
tangentially
2.5 m
4
3 m
2.5 m
5 m
3.0 m
6 m
3.0 m
7 m
4.5 m
8
9 m
2.5 m
4
4 m
3.0 m
5 m
3.5 m
6 m
4.0 m
8 m
4.5 m
8
8 m
3.0 m
4
5 m
7 m
4.0 m
5.0 m
8 m
5.0 m
9 m
4.0 m
8
10 m
4.0 m
4
5 m
4.5 m
6 m
5.0 m
8 m
4.0 m
10 m
4.0 m
8
13 m
b) Sensor connection terminals
c) Indoor switch
d) Indoor two-circuit switch, manual,
automatic
e) Indoor two-way switch, automatic,
manual override
Several sensors connected in parallel
(not illustrated)
In this case, it is important not to exceed
a sensor's maximum connected rating.
In addition, all units must be connected to
the same phase.
15
radially
2.0 m
2.5 m
3.0 m
3.0 m
3.5 m
3.0 m
3.0 m
3.0 m
3.0 m
3.5 m
3.0 m
3.5 m
3.5 m
4.0 m
3.5 m
3.0 m
3.0 m
4.0 m
4.5 m
5.5 m