Inspecting Heater - Desa GWN20TA Safety Information And Installation Manual

Desa unvented (vent-free) blue flame gas heater safety information and installation manual gwn20ta, gwp20ta, gwn30ta, gwp30ta, wmn20a, wmp20a
Table of Contents

Advertisement

INsPeCTING HeATeR

Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 22 shows a correct pilot flame pattern.
Figure 23 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 23
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 16)
• see Troubleshooting, page 19
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue
and have no yellow or orange color.
Thermocouple
Figure 22 - Correct Pilot Flame Pattern
Thermocouple
Figure 23 - Incorrect Pilot Flame Pattern
119344-01B
Blue Flame
Pilot Burner
Yellow Flame
Pilot
Burner
www.desatech.com
BURNER FLAME PATTERN
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide.
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
Figure 24 shows a correct burner flame pat-
tern. Figure 25 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame.
It also shows the flame higher than 1/2 the
glass panel height.
If burner flame pattern is incorrect, as shown
in Figure 25
• turn heater off (see To Turn Off Gas To
Appliance, page 16)
• see Troubleshooting, page 19
Figure 24 - Correct Burner Flame Pattern
Figure 25 - Incorrect Burner Flame
Blue
Flame
/
1
Height
1
Height
Pattern
Glass

Yellow
Tipping
/
Glass

17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwp20taGwp30taGwn30taWmn20aWmp20a

Table of Contents