Desa CFS18NR Owner's Operation And Installation Manual

Unvented (vent-free) natural gas log heater

Advertisement

DESA INTERNATIONAL
UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATER
Variable Manually-Controlled Models Also Design-Certified As
OWNER'S OPERATION AND INSTALLATION MANUAL
CFS18NR, VS18NR,
VS24NR VS30NR
18", 24", and 30"
Remote-Ready Models
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Vented Decorative Appliances
Save this manual for future reference
WARNING: Improper installation, ad-
justment, alteration, service, or mainte-
nance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational proce-
dures. For assistance or additional in-
formation consult a qualified installer,
service agency, or the gas supplier.
WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry or UL127 factory-built fire-
place, or in an approved ventless fire-
box. It is design-certified for these
installations in accordance with ANS
Z21.11.2. Exception: Do not install
this appliance in a factory-built fire-
place that includes instructions stat-
ing it has not been tested or should
not be used with unvented gas logs.
®

Advertisement

Table of Contents
loading

Summary of Contents for Desa CFS18NR

  • Page 1 DESA INTERNATIONAL UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER Variable Manually-Controlled Models Also Design-Certified As OWNER’S OPERATION AND INSTALLATION MANUAL CFS18NR, VS18NR, VS24NR VS30NR 18", 24", and 30" Remote-Ready Models WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Top Middle Left Front Branch Front Burner Piezo Ignitor Right Front Branch Control Knob Remote Flame Control Adjustment (Optional) Knob Figure 1 - VS24NR Shown LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223, also known as NFPA 54*.
  • Page 4: Air For Combustion And Ventilation

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in-...
  • Page 5: Determining Fresh-Air Flow For Heater Location

    AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6: Ventilation Air

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12"...
  • Page 7: Installation

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater.
  • Page 8 DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER INSTALLATION Continued NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed.
  • Page 9: Mantel Clearances

    INSTALLATION Continued MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood. Determining Minimum Mantel Clearances If you meet minimum clearance between mantel shelf and top of fireplace opening, a...
  • Page 10: Installing Damper Clamp Accessory For Vented Operation

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER INSTALLATION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.
  • Page 11: Connecting To Gas Supply

    INSTALLATION Continued Mark screw locations through holes in front panel of base (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. 4. Remove heater base from fireplace. 5. Drill holes at marked locations using 3/16"...
  • Page 12: Checking Gas Connections

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Page 13: Installing Logs

    INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These numbers will help you identify the log when installing.
  • Page 14: Operating Heater

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
  • Page 15: To Turn Off Gas To Appliance

    OPERATING HEATER Continued 9. Slightly push in and turn control knob counterclockwise the ON position. 10. Wait one minute and switch selector switch to the ON position to light burners. 11. Set flame adjustment knob to any level between HI and LO. CAUTION: Do not try to ad- just heating levels by using the manual shutoff valve.
  • Page 16 DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER OPERATING HEATER Continued 3. Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.
  • Page 17: Inspecting Burners

    INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool.
  • Page 18: Cleaning And Maintenance

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot When ignitor button is pressed, there is...
  • Page 20 DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner...
  • Page 21 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 22: Specifications

    TECHNICAL SERVICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). You can also visit DESA International’s technical services site www.desatech.com. REPLACEMENT PARTS Note: Use only original replacement parts.
  • Page 23 ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.
  • Page 24: Illustrated Parts Breakdown

    DESA INTERNATIONAL UNVENTED NATURAL GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN VARIABLE CONTROL CFS18NR VS18NR VS24NR VS30NR 10-2 10-1 103449...
  • Page 25: Parts List

    PARTS LIST CFS18NR VS18NR VS24NR VS18NR/CFS18NR VS30NR 103580-04 103576-01 103577-02 103578-02 103579-02 M11084-26 103779-01 098249-01 103780-01 101330-01 10-1 101008-01 10-2 101007-01 100999-04 103984-01 098271-01 102445-01 103588-01 103782-01 M12461-26 103781-01 098264-02 103784-02 103784-01 103587-01CK M11084-26 099387-12 100609-01 101004-11 101004-11 103783-01 099998-01...
  • Page 26: Warranty Information

    VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.

This manual is also suitable for:

Vs18nrVs24nrVs30nr

Table of Contents