Maintenance; Maintenance Schedule - Honeywell HW2000i - Portable Inverter Generator Owner's Manual

Inverter generator
Hide thumbs Also See for HW2000i - Portable Inverter Generator:
Table of Contents

Advertisement

MAINTENANCE

Maintenance Schedule

Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and
inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3).
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
• Shut off engine before performing any maintenance. If
engine must be run, be sure area is well ventilated.
NOTICE
Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.
MAINTENANCE TASK
Fill fuel tank
Check engine oil level
Check air cleaner
Clean air cleaner
Change engine oil (HW1000i)
Change engine oil (HW2000i)
Check/clean spark plug
Clean spark arrestor
Check/adjust valve clearance
Clean fuel tank and strainer
Check fuel line
TABLE 3. Generator Maintenance Schedule
* Perform at every indicated month or operating hour interval, whichever comes first.
† Clean more often when using generator in dusty areas.
‡ HW2000i model only.
** It is recommended that this maintenance task be performed by a service dealer.
HW1000i / HW2000i Inverter Generator Owner's Manual
Only use OUTSIDE and far
away from windows, doors, and
vents.
First month
Before
or 25 hours
each use
of use
X
X
X
X
Every 2 years (replace if necessary)**
Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug.
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seri-
ously hurt or killed. Always follow inspection and mainte-
nance recommendations and schedules in this owner's
manual.
NOTICE
The maintenance schedule applies to normal operating con-
ditions. If you operate generator under severe conditions,
such as sustained high-load or high-temperature, or use it in
unusually wet or dusty conditions, consult your servicing
dealer for recommendations applicable to your individual
needs and use.
*
FREQUENCY
Every 3
Every 4
months or
months or
50 hours of
62.5 hours
use
of use
X
X
www.honeywellgenerators.com
Every 6
Every
months or
year or
100 hours of
200 hours
use
of use
X
X
**
X
X
**
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hw1000i

Table of Contents