M
M
ENU
ODE
KEYER G
019 KEY CW MEM1
Function: Permits entry of the CW message for message
register 1.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tun-
ing Dial knob and [ CLAR/VFO-B ] knob.
tyP2: You may enter the CW message from the CW keyer.
020 KEY CW MEM2
Function: Permits entry of the CW message for message
register 2.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tun-
ing Dial knob and [ CLAR/VFO-B ] knob.
tyP2: You may enter the CW message from the CW keyer.
021 KEY CW MEM3
Function: Permits entry of the CW message for message
register 3.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tun-
ing Dial knob and [ CLAR/VFO-B ] knob.
tyP2: You may enter the CW message from the CW keyer.
022 KEY CW MEM4
Function: Permits entry of the CW message for message
register 4.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tun-
ing Dial knob and [ CLAR/VFO-B ] knob.
tyP2: You may enter the CW message from the CW keyer.
023 KEY CW MEM5
Function: Permits entry of the CW message for message
register 5.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the Main Tun-
ing Dial knob and [ CLAR/VFO-B ] knob.
tyP2: You may enter the CW message from the CW keyer.
Page 110
ROUP
GENERAL G
024 GENE ANT SEL
Function: Sets the method of antenna selection.
Available Values: bAnd/rEG
Default Setting: bAnd
bAnd: The antenna is selected in accordance with the op-
erating band.
rEG: The antenna is selected in accordance with the band
stack (different antennas may be utilized on the
same band, if so selected in the band stack).
025 GENE BEP LVL
Function: Sets the beep level.
Available Values: 0 ~ 100
Default Setting: 50
026 GENE CAT BPS
Function: Sets the transceiver's computer-interface cir-
cuitry for the CAT baud rate to be used.
Available Values: 4800/9600/192H (19200)/384H
(38400) bps
Default Setting: 4800 bps
027 GENE CAT TOT
Function: Sets the Time-Out Timer countdown time for a
CAT command input.
Available Values: 10/100/1000/3000 msec
Default Setting: 10 msec
The Time-Out Timer shuts off the CAT data input after the
continuous transmission of the programmed time.
028 GENE CAT RTS
Function: Enables/Disables the RTS port of the CAT jack.
Available Values: On/OFF
Default Setting: On
029 GENE MEM GRP
Function: Enables/Disables Memory Group Operation.
Available Values: On/OFF
Default Setting: OFF
030 GENE Q SPLIT
Function: Selects the tuning offset for the Quick Split fea-
ture.
Available Values: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz
031 GENE TX TOT
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF/1 ~ 30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after con-
tinuous transmission of the programmed time.