TX AUDIO G
135 tAUd PE2 FRQ
Function: Selects the center frequency of the middle range
for the parametric microphone equalizer when the speech
processor is activated.
Available Values: OFF/700 ~ 1500 Hz (100 Hz/step)
Default Setting: 800 Hz
OFF:
The equalizer gain and Q-factor are set
to factory defaults (flat).
700 ~ 1500: Center frequencies of 700 Hz ~ 1500 Hz.
You may adjust the equalizer gain and
Q-factor at this selected audio frequency
via menu items "136 tAUd PE2 LVL"
and "137 PE2 BW."
136 tAUd PE2 LVL
Function: Adjusts the equalizer gain of the middle range
of the parametric microphone equalizer when the speech
processor is activated.
Available Values: –10 ~ +10
Default Setting: –3
137 tAUd PE2 BW
Function: Adjusts the Q-factor of the middle range of the
parametric microphone equalizer when the speech proces-
sor is activated.
Available Values: 1 ~ 10
Default Setting: 1
138 tUAd PE3 FRQ
Function: Selects the center frequency of the high range
for the parametric microphone equalizer when the speech
processor is activated.
Available Values: OFF/1500 ~ 3200 Hz (100 Hz/step)
Default Setting: 2100 Hz
OFF:
The equalizer gain and Q-factor are set
to factory defaults (flat).
1500 ~ 3200: Center frequencies of 1500 Hz ~ 3200 Hz.
You may adjust the equalizer gain and
Q-factor in this selected audio fre-
quency via menu items "139 tUAd PE3
LVL" and "140 tUAd PE3 BW."
139 tUAd PE3 LVL
Function: Adjusts the equalizer gain of the high range of
the parametric microphone equalizer when the speech pro-
cessor is activated.
Available Values: –10 ~ +10
Default Setting: +6

140 tUAd PE3 BW

Function: Adjusts the Q-factor of the high range of the
parametric microphone equalizer when the speech proces-
sor is activated.
Available Values: 1 ~ 10
Default Setting: 1
FT-2000D O
ROUP
M
M
TX GNRL G
141 tGEn BIAS
Function: Selects the Final Amplifier's operation between
the "Class-A" and "Class-AB" mode, and adjusts the Bias
level while in "Class-A" operation.
Available Values: Ab "Class-AB"/0 ~ 100 "Class-A"
Default Setting: Ab
142 tGEn MAX PWR
Function: Selects a maximum output power limit.
Available Values: 20/50/100/200 W
Default Setting: 200 W
143 tGEn PWRCTRL
Function: Configures the [ RF PWR ] knob.
Available Values: ALL/CAr
Default Setting: ALL
ALL:The [ RF PWR ] knob is enabled on all modes.
CAr: The [ RF PWR ] knob is enabled in all modes
except SSB. In this configuration, the SSB out-
put power will be set to maximum, regardless
of the [ RF PWR ] knob's position.
144 tGEn ETX-GND
Function: Enables/Disables the TX GND jack on the rear
panel.
Available Values: EnA(ENABLE)/diS(DISABLE)
Default Setting: diS(DISABLE)
145 tGEn TUN PWR
Function: Selects a maximum output power limit for driv-
ing the input circuit of an external linear RF amplifier
while tuning (while using the Remote Control function
of the linear RF amplifier).
Available Values: 20/50/100/200 W
Default Setting: 100 W
146 tGEn VOX SEL
Function: Selects the audio input source for triggering
TX during VOX operation.
Available Values: nic/dAtA
Default Setting: nic
nic(MIC):
The VOX function will be activated
by microphone audio input.
dAtA(DATA): The VOX function will be activated
by data audio input.