Download Print this page
Delta Electronics Function Card DVP-EH Instruction Manual

Delta Electronics Function Card DVP-EH Instruction Manual

Delta electronics network adapter instruction manual

Advertisement

Quick Links

Warning
This Instruction Sheet only provides descriptions for electrical specifications, general specifications, installation &
wiring. Other detail infromation about programming and intructions is compatible with SV series; please see PLC
Application Manual. For more information about the optional peripherals, please see individual product instuction
shee or "DVP-PLC Application Manual: Special module".
This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne dust, humidity, electric
shock risk and vibration. Also, it is equipped with protective methods such as some special tools or keys to open the
enclosure, in order to prevent hazard to users or damage the PLC.
Do NOT connect the AC main circuit power supply to any of the input/output terminals, or it may damage the PLC.
Check all the wiring prior to power up. To prevent any electromagnetic noise, make sure the PLC is properly
grounded
. Do NOT touch terminals when power on.
Introduction
Product Profile & Outline
Communication port cover
3
4
5
2
I/O terminal cover
1
Function card/memory card cover
6
I/O terminals
7
I/O terminal No.
8
Extension module connection port cover
Input indicator
10
Output indicator
DIN rail clip
5
9
9
4
DIN rail (35mm)
Mounting screws
6
2
Direct mounting hole
1
7
Battery socket
Function card mounting hole
8
1
Memory card port
POWER/RUN/BAT.LOW/ERROR indicator
3
5
2
4
Extension module connection port
Dimension
Model
W (mm)
W1 (mm)
DVP16EH00R/T
113
103
DVP20EH00R/T
113
103
DVP32EH00R/T
143.5
133.5
DVP32EH00M
158.8
153.8
DVP40EH00R/T
158.8
153.8
DVP48EH00R/T
174
164
W1
DVP64EH00R/T
212
202
W
82.2
DVP80EH00R/T
276
266
Specifications
Model
16EH00
20EH00
32EH00
32EH00M 40EH00
Item
Power supply
100 ~ 240V AC (-15% ~ 10%), 50/60Hz ± 5%
voltage
Fuse capacity
2A/250V AC
Power consumption
50VA
50VA
60VA
60VA
DC24V current
500mA
500mA
500mA
500mA
500mA
supply
Power protection
DC24V; output short-circuit
Withstand voltage
1,500V AC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE)
Insulation resistance
> 5M (all I/O point-to-ground: 500V DC)
ESD: 8KV Air Discharge, EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O:
250V
Noise immunity
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz~1GHz, 10V/m
The diameter of grounding wire shall not be less than that of L, N terminal of the power. (When
Earth
many PLCs are in use at the same time, please make sure every PLC is properly grounded.)
Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), pollution degree: 2
Operation/storage
Storage: -40°C ~70°C (temperature), 5 ~ 95% (humidity)
Vibration/shock
International standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
immunity
Weight (g)
500/480
520/500
652/612
644
710/675
Input Point Specification
Spec.
Differential input
24V DC single common port input
Items
5VDC two inputs
Low speed
High speed 200KHz
Independent
Input wiring type
Change wiring from S/S to SINK or SOURCE
wiring
Input indicator
LED display, light on = ON, light off = OFF
Input voltage
5V DC
24V DC
X0~X7,X12,X13,X16,X17,X20~X47: > 18.5V
Off → On
> 5mA
Active
X10,X11,X14,X15: > 16.5V
Level
On → Off
< 2mA
X0~X47: < 8V DC
Response time/
0.5us
10ms
0.5us
noise immunity
Output Point Specification
Spec.
Single common port transistor output
Two differential
Items
outputs
Low speed
High speed
Max. frequency
200KHz
10KHz
200KHz
Output indicator
LED display, light on = ON, light off = OFF
Min. load
-
Working voltage
5V DC
5 ~ 30V DC
Insulation
Line Driver
Photocoupler
Current
< 25mA
0.3A/1 point @ 40°C
30mA
specification
Off
O n, 20us
Max. output
0.2us
0.2us
delay time
On
O ff, 30us
Over-current
N/A
protection
Note: Differential output points are only Y0 ~ Y3 on DVP32EH00M; other output points are for relay output.
Installation & Wiring
ENGLISH
3.1 PLC Mounting Arrangements and Wiring Notes
How to install DIN rail:
DVP-PLC can be secured to a cabinet by using the DIN rail of 35mm in height and
7.5mm in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop
any side-to-side movement of PLC and reduce the chance of wires being loosen. A small
retaining clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the
rail and gently push it up. To remove it, pull the retaining clip down and gently remove
PLC from DIN rail, as shown in the figure.
How to screw: Please use M4 screw according to the dimension of the product.
> 50mm
Please install PLC in an enclosure with sufficient space around it to allow heat
DVP MPU
> 50mm
> 50mm
dissipation as shown in the figure.
> 50mm
Wiring:
1. Use O-type or Y-type terminal. See the figure in the left hand side for its
specification. PLC terminal screws should be tightened to 5 ~ 8 kg-cm (4.3 ~
Below 6.2
6.9 in-Ibs) and please use only 60/75ºC copper conductor.
2. DO NOT wire empty terminal • . DO NOT place the input signal cable and
To suit M3.5 screw terminals
output power cable in the same wiring circuit.
Below 6.2
3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring.
Tear off the sticker on the heat dissipation hole for preventing alien
substances from dropping in, to ensure normal heat dissipation of the PLC.
3.2 Wiring Notes
Power Input Wiring
The power input of DVP-EH series is AC. When operating the PLC, please make sure that:
1. The input voltage should be current and its range should be 100 ~ 240V AC. The power should be
connected to L and N terminals. Wiring AC110V or AC220V to +24V terminal or input terminal will result in
serious damage on the PLC.
2. The AC power input for PLC MPU and I/O extension modules should be ON or OFF at the same time.
3. Use wires of 1.6mm (or longer) for the grounding of PLC MPU. The power shutdown of less than 10ms will
not affect the operation of the PLC. However, power shutdown time that is too long or the drop of power
voltage will stop the operation of the PLC and all outputs will go OFF. When the power supply turns normal
again, the PLC will automatically return to its operation. Please be aware of the latched auxiliary relays and
registers inside the PLC when programming.
AC Power Input
100~240VAC
L
N
+24V 24G
2.0 A
DC/DC
0.5A is the maximum power supply for +24V power supply output terminal. DO NOT connect other
external power supplies to this terminal. Every input terminal requires 6 ~ 7mA to be driven; e.g. the
16-point input will require approximately 100mA. Therefore, +24V cannot give output to extermal load
that is more than 400mA.
Safety Wiring
Since a PLC controls many devices, actions of any device may affect actions of other devices, and the
breakdown of any one device may cause the breakdown of the whole auto-control system and danger.
48EH00
64EH00
80EH00
Therefore, we suggest you wire a protection circuit at the power input terminal, as shown in the figure below.
5
M C
4
60VA
60VA
80VA
80VA
8
2
500mA
500mA
500mA
G ua r d
Limit
MC
3
M C
L
N
7
6
Input Point Wiring
There are two types of DC inputs, SINK and SOURCE.
Input point loop equivalent circuit
DC Signal IN
748/688
836/756
948/848
S/S
Sinking
+24V
X0
Note
SINK mode
(common port for current
1. Differential input is only for
input S/S)
X0, X1, X4 and X5 on
DVP32EH00M.
Input point loop equivalent circuit
DC Signal IN
2. Only X0, X1, X4 and X5 on
DVP32EH00M are equipped
X0
with high-speed input.
+24V
24G
Input point X0 ~ X7, X10 ~
S/S
X17 can conduct 10 ~ 60ms
Sourcing
S/S
digital filter adjustment
SOURCE mode
(common port for current
output S/S)
Wiring of Differential Input
Single common port relay output
X0 ~ X1 and X4 ~ X5 of DVP32EH00M are all high-speed input circuit and others are DC24V input. The
Load ON/OFF control
working frequency of high-speed input circuit can reach up to 200KHz and is mainly for connecting to
differential (double-wire) LINE DRIVER output circuit. In an low-noise and low-frequency (less than 50KHz)
2mA/DC power supply
environment, you may also use DC5V SINK/SOURCE input of a single port or series-connect a 2K /0.5W
< 250V AC, 30V DC
resistance for transferring into DC24V SINK/SOURCE input of a single port.
Magnetic
Wiring in a high-speed, high-noise environment
2A/1 point (5A/COM)
DVP32EH00M high-speed output
75VA (conductive), 90W (resistive)
10ms
Wiring of DVP32EH00M DC5V SINK
X0+
(5V SINK)
X0 -
Wiring of from DC5V to DC24V SINK
2K / 0.5W
X0+
(24V SINK)
SENSOR
X0 -
Output Point Wiring
Relay (R) contact circuit wiring
DVP-**-**-**-R
LOAD
Y0
LED
RY
C0
RELAY OUTPUT
Flywheel diode: To extend the life span of contact
Fuse: Uses 5 ~ 10A fuse at the common port of output contacts to protect the output circuit.
Varistor: To reduce the interference on AC load
DC power supply
AC power supply
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to
ensure safety protection in case of any unexpected errors.
Transistor (T) contact circuit wiring
DVP-**-**-**-T
Y0
LED
C0
TRANSISTOR OUTPUT
DC power supply
Circuit protection fuse
Due to all outputs are Open Collectors, if Y0 is set as pulse output, the output current has to be bigger than 0.1A to
ensure normal operation of the transistor module.
Due to all outputs are Open Collectors, if Y1 is set as pulse output, the output current has to be bigger than 0.1A to
ensure normal operation of the transistor module.
S/S
X0
X1
X2
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to
ensure safety protection in case of any unexpected errors.
+5V
Wiring of Differential Output
Y0
Y1
AC power supply load
Power circuit protection fuse (3A
1
Power indicator
Emergency stop
This button can cut off the system power supply when accidental
emergency takes place.
System circuit isolation device
The device is made of electromagnetic contactor and relay as the
1
switch to prevent the instability of system when the power is
intermittently supplied.
DVP-PLC (main processing unit)
Earth
Power supply
AC: 100 ~ 240V AC, 50/60Hz; DC: 240V DC
Wiring loop
SINK
24VDC
+5V
24G
S/S
+24V
24G
S/S
X0
X1
X2
X0
Sink Type
Wiring loop
SOURCE
24VDC
+5V
+24V
24G
S/S X0
X1 X2
X0
Source Type
Encoder output
X0+
A +
A
X0 -
A -
Twisted pair
Differential output
cable
X1+
B +
B
X1 -
B -
Wiring of DVP32EH00M DC5V SOURCE
PNP
SENSOR
NPN
+
X0+
SENSOR
+
5V
5V
(5V SOURCE)
X0 -
Wiring of from DC5V to DC24V SOURCE
PNP
DC24V
SENSOR
NP N
+
2K
/ 0.5W
+
24V
X1+
24V
(24V SOURCE)
X1 -
5
C0
Y0
Y1
C1
Y4
Y5
Y6
Y7
2
3
9
POWER
1
6
MC1
MC2
3
10
2
4
7
8
Emergency stop: Uses external switch
Empty terminal: not in use
Neon indicator
Incandescent light (resistive load)
Tr a n sisto r o u tp u t Exa m p le (sin k o u tpu t wi rin g )
5
6
7
7
4
LOAD
C0
Y0
Y 1 C 1 Y 4 Y 5 Y 6
Y 7
< 0.5A
MC 1
MC 2
1
2
3
3
Emergency stop
Empty terminal
PL C
Driv e r
Y0+
A +
Circuit for Photocouple
Y0-
A -
Twi sted
SG 0
pair cable
Y1+
B +
Circuit for Line Receiver
Y1-
B -
注 意 事 項
SV
DVP-PLC
(OPEN TYPE)
產 品 簡 介
產 品 外 觀 及 各 部 介 紹
3
5
2
4
1
6
7
8
10
DIN
5
9
9
4
DIN
(35mm)
6
2
1
7
8
1
3
2
4
5
外 觀 及 尺 寸
W (mm)
W1 (mm)
DVP16EH00R/T
113
103
DVP20EH00R/T
113
103
DVP32EH00R/T
143.5
133.5
DVP40EH00R/T
158.8
153.8
DVP48EH00R/T
158.8
153.8
DVP64EH00R/T
212
202
W1
DVP80EH00R/T
276
266
W
82 .2
電 氣 規 格
16EH00
20EH00
32EH00
32EH00M
40EH00
48EH00
64EH00
100 ~ 240V AC (-15% ~ 10%), 50/60Hz ± 5%
2 A / 250VAC
50VA
50VA
60VA
60VA
60VA
60VA
80VA
500mA
500mA
500mA
500mA
500mA
500mA
500mA
DC24V
1.500V AC (Primary-secondary) 1,500V AC (Primary-PE) 500V AC (Secondary-PE)
5 M
500V DC
ESD: 8KV Air Discharge EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m
L, N
PLC
0°C ~ 55°C
50 ~ 95%
2
-40°C ~ 70°C
5 ~ 95%
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
g
500/480
520/500
652/612
644
710/675
748/688
836/756
輸 入 點 規 格
24V DC
5V DC
200KHz
S/S
SINK
SOURCE
1.
DVP32EH00M
LED
'ON'
'OFF'
X0, X1, X4,
5V DC ± 10%
24V DC ± 10%
X5
X0~X7,X12,X13,X16,X17,X20~X47 > 18.5V
2. DVP32EH00M
Off → On
> 5mA
X10,X11,X14,X15 > 16.5V
X0~X47 < 8V DC
X0, X1, X4, X5
On → Off
< 2mA
X0 ~ X7 X10 ~
0.5us
10 ms
0.5us
X17
10 ~ 60 ms
輸 出 點 規 格
200KHz
10KHz
200KHz
ON/OFF
LED
'ON'
'OFF'
-
2mA/DC
5VDC ± 10%
5 ~ 30V DC
< 250V AC, 30V DC
2A/1
(5A/COM)
25mA
0.3A/1
@ 40°C
30mA
75VA
Off→On
20us
0.2us
0.2us
10ms
On→Off
30us
DVP32EH00M
Y0 ~ Y3
繁 體 中 文
繁 體 中 文
繁 體 中 文
繁 體 中 文
DVP-PLC
/
80EH00
80VA
500mA
948/848
,
90W

Advertisement

loading

Summary of Contents for Delta Electronics Function Card DVP-EH

  • Page 1 Specifications Item Power supply voltage Fuse capacity Power consumption DC24V current supply Power protection Withstand voltage Insulation resistance Noise immunity Earth Operation/storage Vibration/shock immunity Weight (g) Input Point Specification Items Input wiring type Input indicator Input voltage Active Level Response time/ noise immunity Output Point Specification Items...