Environmental
Temperature:
Operating
Storage
Relative humidity
Maximum vibration:
Operating
Storage
Maximum shock:
Nonoperating (half-sine pulse)
Nonoperating (faired-square
wave)
Altitude:
Operating
Storage
System Setup
Overview
Use system setup as follows:
•
To change the system configuration information after you add, change, or remove any
hardware in your computer
•
To set or change a user-selectable option such as the user password
•
To read the current amount of memory or set the type of hard drive installed
Before you use system setup, you must know the kind of floppy drive(s) and hard drive(s) installed
in your computer. It is recommended that you write down the system setup screen information for
future reference.
NOTICE:
changes can make your computer work incorrectly.
82
Appendix
Unless you are an expert computer user, do not change the settings for this program. Certain
10 to 35 C (50 to 95 F)
NOTE:
At 35°C (95°F), the maximum operating altitude is
914 m (3000 ft).
–40 to 65 C (–40 to 149 F)
20% to 80% (noncondensing)
0.25 G at 3 to 200 Hz
2.20 Grms at 10 to 500 Hz
105 G, 2 ms
32 G with a velocity change of 596.9 cm/sec (235
inches/sec)
–15.2 to 3048 m (–50 to 10,000 ft)
NOTE:
At 35°C (95°F), the maximum operating altitude is
914 m (3000 ft).
–15.2 to 10,670 m (–50 to 35,000 ft)