Casio FX-7400GII - SOFTWARE VERSION 2-00 User Manual page 143

Software version 2.00
Hide thumbs Also See for FX-7400GII - SOFTWARE VERSION 2-00:
Table of Contents

Advertisement

• Display (pie graph value display setting)
• {%}/{Data} ... For each data element {display as percentage}/{display as value}
• % Sto Mem (Specifies storage of percentage values to a list.)
• {None}/{List} ... For percentage values: {Do not store to list}/{Specify List 1 to 26 and store}
When "Box" (med-box graph) is selected as the Graph Type:
• Outliers (outliers specification)
• {On}/{Off} ... {display}/{do not display} Med-Box outliers
When "Bar" (bar graph) is selected as the Graph Type:
• Data1 (first stick data list)
• {LIST} ... {List 1 to 26}
• Data2 (second stick data list)/Data3 (third stick data list)
• {None}/{LIST} ... {none}/{List 1 to 26}
• Stick Style (stick style specification)
• {Leng}/{HZtl} ... {length}/{horizontal}
2. Graph draw/non-draw status
The following procedure can be used to specify the draw (On)/non-draw (Off) status of each of
the graphs in the graph menu.
To specify the draw/non-draw status of a graph
1. Pressing
(GRPH)
screen.
• Note that the StatGraph1 setting is for Graph 1 (GPH1 of the graph menu), StatGraph2 is
for Graph 2, and StatGraph3 is for Graph 3.
2. Use the cursor keys to move the highlighting to the graph whose status you want to change,
and press the applicable function key to change the status.
• {On}/{Off} ... {On (draw)}/{Off (non-draw)}
• {DRAW} ... {draws all On graphs}
3. To return to the graph menu, press
• V-Window parameters are normally set automatically for statistical graphing. If you want to
set V-Window parameters manually, you must change the Stat Wind item to "Manual".
While the statistical data list is on the display, perform the following procedure.
Note that V-Window parameters are set automatically for the following types of graphs
regardless of whether or not the Stat Wind item is set to "Manual".
Pie, 1-Sample
t
Sample
Test,
• The default setting automatically uses List 1 data as
y
as
-axis (vertical) values. Each set of
(SEL) displays the graph On/Off
(SET UP)
(Returns to previous menu.)
Z
Z
Test, 2-Sample
Test, 1-Prop
2
GOF Test,
2
2-way Test, 2-Sample
.
(Man)
Z
Test, 2-Prop
F
Test (
x
-axis (horizontal) values and List 2 data
x
y
/
data is a point on the scatter diagram.
6-3
[GRPH]-[SEL]
Z
t
Test, 1-Sample
Test, 2-
x
-axis only disregarded).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents