Troubleshooting Guide - Danby dac10007ee Use And Care Manual

Danby products room air conditioner use and care manual
Hide thumbs Also See for dac10007ee:
Table of Contents

Advertisement

Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a
possible solution. If the unit continues to operate improperly, call Danby's Toll Free Number 1-800-263-2629 for
assistance, or call one of our service depots listed in the enclosed "Authorized Service Depot" listing provided
with this unit.
Difficulty
Air conditioner will
not operate.
Inefficient or no cooling.
Noisy unit.
Odors.
Water dripping outside.
Water dripping inside.
Ice or frost build-up.
NOTES:
1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a
qualified technician.
2. When unit is installed using proper installation steps, unit is properly tipped towards the outdoors
to allow for condensation run-off.

Troubleshooting Guide

Possible Cause
No power to unit.
Dirty air filter.
Unit size inappropriate
for application.
Blocked air flow.
Power interruption, settings
changed too quickly, or
compressor overload tripped.
Loose parts.
Inadequate support.
Formation of mold, mildew, or
algae on wet surfaces.
Hot and humid weather.
Unit is not properly angled to
allow water to drain outside.
Low outside temperature.
Unit air filter is dirty.
Suggested Solution
Check connection of power cord to
power source.
Check fuse or circuit breaker.
Clean or replace air filter.
Check with dealer to determine proper unit
capacity for application.
Remove obstruction from grill or
outdoor louvers.
Turn the unit off and wait 5 minutes before
attempting to re-start.
Tighten loose parts.
Provide additional support to unit.
Clean unit thoroughly.
Place algaecide tablet in base pan.
Condensation run-off is normal under these
conditions.
Unit must be installed on an angle for proper
condensation run-off. Check the unit and
make any adjustments.
When outdoor temperature is approximately
65°F or below, frost may form when unit is in
cooling mode. Switch unit to FAN (only)
operation until frost melts.
Remove and clean filter.