List of Parameters
Parameter
Name
No. (Reg-
ister No.
(Hex))
n20
S-shape
accel-
(0114)
eration/
decel-
eration
charac-
teristic
Description
Used to set S-shape acceleration/de-
celeration characteristics.
0: No S-shape acceleration/decelera-
tion (trapezoidal acceleration/de-
celeration)
1: S-shape acceleration/deceleration
characteristic time 0.2 s
2: S-shape acceleration/deceleration
characteristic time 0.5 s
3: S-shape acceleration/deceleration
characteristic time 1.0 s
Note When the S-shape accelera-
tion/deceleration characteristic
time is set, the acceleration
and deceleration times will be
lengthened according to the
S-shape at the beginning and
end of acceleration/decelera-
tion.
Setting
Default
range
setting
0 to 3
0
Chapter 3
Changes
Memo
during
opera-
tion
No
3-5