Omron SYSDRIVE 3G3JV Setup Manual page 28

Compact simplified inverters
Hide thumbs Also See for SYSDRIVE 3G3JV:
Table of Contents

Advertisement

Design
100-V AC Models
Protective
Motor protection
f
functions
i
Instantaneous overcurrent
protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power interruption
compensation (selection)
Radiation fin overheated
Grounding protection
Charge indicator
Environ-
Location
ment
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Insulation resistance
Vibration resistance
Degree of protection
1-14
3G3JV-A1001
Protection by electronic thermal
Stops at approx. 250% of rated output current.
Stops in 1 min at approximately 150% of rated output cur-
rent.
Stops when main-circuit DC voltage is approximately 410 V.
Stops when main-circuit DC voltage is approximately 160 V.
None (Stops at 15 ms or longer.)
Select between continuing operation if power is restored
within approx. 0.5 s or continuing operation regardless of
length of interruption.
Detected at 110°C ±10°C
Rated output current level protection
CHARGE indicator lights until the main circuit DC voltage
reaches 50 V or less.
Indoors (with no corrosive gas, dust, etc.)
–10 to 50°C
95% max. (with no condensation)
–20 to 60°C
1,000 m max.
5 MΩ min. (Do not carry out any insulation resistance or
withstand voltage tests.)
2
9.8 m/s
max. between 10 and 20 Hz, 2.0 m/s
tween 20 and 50 Hz
Mounted in a panel (equivalent to IP20)
Chapter 1
3G3JV-A1002
2
max. be-

Hide quick links: