Download Print this page
Omron E2Q5 Datasheet
Omron E2Q5 Datasheet

Omron E2Q5 Datasheet

Long distance square inductive proximity sensor

Advertisement

Quick Links

Long Distance Square Inductive Proximity Sensor
E2Q5
• M12 Plug-in connection
• Integrated short circuit and
reverse polarity protection
• Active face positioning:
Y-axis 15°, X-axis 90°
incremets
Ordering Information
Sensing
Connection
distance
20 mm
shielded
Plug-in
connector
40 mm
non-shielded
E2Q5
Square Proximity Sensor
Active
face
NPN
PNP
Changable
NPN
PNP
Output
NO
E2Q5-N20E1-M1
E2Q5-N20E3- M1
E2Q5-N20F1-M1
E2Q5-N20F3- M1
E2Q5-N40ME1-M1
E2Q5-N40ME3- M1
E2Q5-N40MF1-M1
E2Q5-N40MF3- M1
NO + NC
D-1

Advertisement

loading

Summary of Contents for Omron E2Q5

  • Page 1 Long Distance Square Inductive Proximity Sensor E2Q5 Square Proximity Sensor • M12 Plug-in connection • Integrated short circuit and reverse polarity protection • Active face positioning: Y-axis 15°, X-axis 90° incremets Ordering Information Output Sensing Active Connection distance face NO + NC...
  • Page 2 Ambient humidity 35 to 95% RH Influence of temperature ± 10% max. of Sn at 23° in temperature range of -25° to 70°C Dielectric strength 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC...
  • Page 3 Indicator Proximity Black (yellow) Sensor main E2Q5-N20E1-M1 circuits E2Q5-N40ME1-M1 Blue Yellow indicator Connector Pin Arrangement Control output Note: Terminal 2 is not used Brown Non-sensing zone Sensing zone 4.7kΩ 4.7kΩ Load Sensing Operation object Indicator Black (yellow) Proximity Load...
  • Page 4: Dimensions (Unit:mm)

    Sensing Indicator circuits object (yellow) Load 4.7kΩ E2Q5-N20F1-M1 Blue E2Q5-N40MF1-M1 Yellow indicator Connector Pin Arrangement Control output Note: Terminal 2 is not used Brown Non-sensing zone Sensing zone White Proximity Sensing Sensor object main Black circuits Load Operation Indicator...
  • Page 5 Do not impose an exessive voltage on the E2Q2, otherwise it may explode or burn. Side-by-side Do not connect an AC power supply to any DC model. If AC power (100 VAC or more) is supplied to the sensor, it may ex- plode or burn.
  • Page 6: Maintenance And Inspection

    Proximity Sensor through a Relay ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E47E-EN-01 In the interest of product improvement, specifications are subject to change without notice.

This manual is also suitable for:

E2q5-n20e1-m1E2q5-n20e3-m1E2q5-n20f1-m1E2q5-n20f3-m1E2q5-n40me1-m1E2q5-n40me3-m1 ... Show all