Mounting And Dismounting The Sensor Module - Omron CQM1 Operation Manual

Sysmac cqm1h/cqm1 series dedicated i/o units
Hide thumbs Also See for CQM1:
Table of Contents

Advertisement

Mounting and Dismounting the Sensor Module

Mutual Interference
3-2
Mounting and Dismounting the Sensor Module
Mounting
Dismounting
148
When installing two or more sensors face to face or side by side, ensure that
the minimum distances given in the following table are maintained. Sensors
can be mounted together in parallel, however, if their cable length switches
are set to different values.
Model
E2C-CR5B
E2C-CR8@
E2C-X1A
E2C-C1A
E2C-X1R5A
Mount the E3C-MA11 securely to the Sensor Unit so that the fiber sensor con-
nector side is on the left and the indicator side is on the right.
A pulling tool is provided with the Sensor Unit. To dismount the E3C-MA11
from the Sensor Unit, hook the pulling tool onto the square hole on the right
side of the E3C-MA11 and pull out the E3C-MA11 carefully.
Note Be sure to turn off the CQM1-SEN001 before mounting or dismounting sensor
modules.
A
A
20
20
20
20
20
Pulling tool
Section 3-2
B
Distance (mm)
B
15
15
15
15
15