Specifications
Time Lag Required for Data Conversion
Analog input
Input signal of Analog
Input Unit
0 V
Analog input
Output data of Analog
Input Unit
CQM1-IPS01 Analog Power Supply Unit
CQM1-IPS02 Analog Power Supply Unit
104
2.5 ms x 4 words = 10 ms
No. of connectable Units
Current consumption
Weight
Dimensions
No. of connectable Units
Current consumption
Weight
Dimensions
Time
This step-shaped change is
due to the time lag caused
by the Analog Input Unit's
internal filter circuit.
Time
CQM1-AD041 x 1
420 mA at 5 VDC
145 g
32 x 110 x 107 (W x H x D) mm
CQM1-AD041 x 2
950 mA at 5 VDC
180 g
32 x 110 x 107 (W x H x D) mm