Download Print this page

Omron A165E Datasheet

Emergency stop switch
Hide thumbs Also See for A165E:

Advertisement

Quick Links

Emergency Stop Switch
A165E
Mounting Aperture of
16 mm
• Modular construction, easy installation
• Direct opening mechanism with mini-
mum contact separation of 3 mm in ac-
cordance with EN60947-5-1,
for NC contacts)
• Conforms to EN418, EN60947-5-1.
• Includes a safety lock to prevent mis-
use.
• Features separate construction that al-
lows the Switch to be separated for
easier wiring and one-piece-like con-
struction that allows easier handling.
• High reliability, IP65
• Short mounting depth, less than 28.5
mm below panel
• Quick and easy assembly, snap-in
Switch.
• A165E is identifiable, clearly visible
and will stop a dangerous process,
without creating additional hazards.
Model Number Structure
Model Number Legend
A165E-##-#-#
1 2
3
4
1. Lighted/Non-lighted
None: Non-lighted
L:
Lighted
2. Head Size
S:
30 mm dia.
M:
40 mm dia.
3. Illumination (Operation Voltage/Rated Voltage)
None: Non-lighted
24D: LED (24 VDC)
A165E
Æ
. (only
4. Contacts
01:
SPST (NC)
02:
DPST (NC)
03U: TPST (NC)
One-body, non-lighted models only
G-283

Advertisement

loading

Summary of Contents for Omron A165E

  • Page 1 Emergency Stop Switch A165E Mounting Aperture of 16 mm • Modular construction, easy installation • Direct opening mechanism with mini- mum contact separation of 3 mm in ac- cordance with EN60947-5-1, Æ . (only for NC contacts) • Conforms to EN418, EN60947-5-1.
  • Page 2: Ordering Information

    40 dia. SPST-NC A165E-M-01 None DPST-NC A165E-M-02 TPST-NC A165E-M-03U Note: The above models have a surface indication of “RESET.” Models with “STOP” indication are also available. For further information, contact your OMRON representative. Accessories (Order Separately) Item Appearance Type Model Precautions...
  • Page 3 Insulation resistance 100 MΩ min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity 2,000 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each Dielectric strength terminal and ground...
  • Page 4 No LED is installed for the non-lighted model. Push-lock, Turn-reset System Prevents Misuse Safety Lock Prevents Misuse Even if an object or person touches the pushbutton by mistake, the Contact open contact will not be released unless the pushbutton reaches the lock position.
  • Page 5 Dimensions Note: All units are in millimeters unless otherwise indicated. A165E 30 dia. Non-lighted models Mounting ring 30 mm diameter Note: 1. When applying a coating such as Lock ring paint to the panel, dimensions Packing (T0.5) Lock after the coating must satisfy the +0.1...
  • Page 6 Switch M16¥1 Lock ring Lock Packing (T0.5) +0.1 dia. Note: 1. When applying a coating such as +0.2 dia. paint to the panel, dimensions after the coating must satisfy the specified dimensions. 2. Recommended panel thickness: 0.5 to 3.2 mm.
  • Page 7 45 dia. A16Z-3004 Lock Ring 18 dia. Rough surface 15.8 ±0.1 dia. Rough surface 15 dia. -0.1 Terminal Arrangement SPST Switches DPST Switches TPST Switches Stopper Note: The L+ and L- terminals are not available with the non-lighted models. A165E G-289...
  • Page 8 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. A120-E2-03A-X In the interest of product improvement, specifications are subject to change without notice. G-290 Safety Sensors / Components...