List of Parameters
Para
Reg-
Name
me-
ister
ter
No.
No.
(Hex)
n089
0159
DC injec-
tion brak-
ing current
n090
015A
DC injec-
tion brak-
ing-to-stop
time
n091
015B
Startup DC
injection
braking
time
n092
015C
Stall pre-
vention
during
decelera-
tion
n093
015D
Stall pre-
vention
level dur-
ing accel-
eration
n094
015E
Stall pre-
vention
level dur-
ing opera-
tion
n095
015F
Frequency
detection
level
n096
0160
Overtorque
detection
function
selection 1
n097
0161
Overtorque
detection
function
selection 2
10-22
Description
Used to impose DC on the induction motor for
braking control.
Sets the DC braking current as a percentage
Sets the DC braking current as a percentage
based on the rated current of the Inverter as
100%.
Output
frequency
frequency
Minimum
output
frequency
(n016)
n091
Used to select a function to change the decel-
eration time of the motor automatically so that
there will be no overvoltage imposed on the
motor during deceleration.
0: Stall prevention during deceleration enabled
1: Stall prevention during deceleration disabled
* Be sure to set the parameter to 1 when the
Braking Resistor Unit or a braking resistor is
used as an option.
Used to select a function to stop the accelera-
tion of the motor automatically for stall preven-
tion during acceleration.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
Used to select a function to reduce the output
frequency of the Inverter automatically for stall
prevention during operation.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
Used to set the frequency to be detected.
* The parameter n059 for multi-function out-
put must be set for the output of frequency
detection levels 1 and 2.
Used to enable or disable overtorque detection
and select the processing method after over-
torque detection.
0: Overtorque detection disabled
1: Overtorque detection only when speed coin-
cides and operation continues (issues
alarm)
2: Overtorque detection only when speed coin-
cides and output turned OFF (for protection)
3: Overtorque always detected and operation
continues (issues alarm)
4: Overtorque always detected and output
turned OFF (for protection)
Select the item to detect overtorque.
0: Detected from output torque.
1: Detected from output current.
Set-
Unit
ting
of
range
set-
ting
0 to
1%
100
0.0 to
0.1 s
25.5
0.0 to
0.1 s
25.5
Time
n090
0, 1
1
30 to
1%
200
30 to
1%
200
0.00
0.01
to
Hz
400.0
0 to 4
1
0, 1
1
Chapter 10
Defa
Chan-
Ref-
ult
ges dur-
er-
set-
ing
ence
ting
opera-
page
tion
50
No
6-26
0.5
No
6-26
0.0
No
6-26
0
No
6-27
170
No
6-28
160
No
6-29
0.00
No
6-44
0
No
6-31
0
No
6-32

Hide quick links: