Omron SYSDRIVE 3G3MV SERIES User Manual page 308

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV SERIES:
Table of Contents

Advertisement

List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
(Hex)
n019
0113
Acceleration
time 1
n020
0114
Deceleration
time 1
n021
0115
Acceleration
time 2
n022
0116
Deceleration
time 2
n023
0117
S-shape
acceleration/
deceleration
characteristic
n024
0118
Frequency
reference 1
n025
0119
Frequency
reference 2
n026
011A
Frequency
reference 3
n027
011B
Frequency
reference 4
n028
011C
Frequency
reference 5
n029
011D
Frequency
reference 6
n030
011E
Frequency
reference 7
n031
011F
Frequency
reference 8
n032
0120
Inching fre-
quency com-
mand
10-6
Description
Acceleration time: The time required
to go from 0% to 100% of the maxi-
mum frequency.
Deceleration time: The time required
to go from 100% to 0% of the maxi-
mum frequency.
* The actual acceleration or decel-
eration time is obtained from the
following formula.
Acceleration/Deceleration time =
Acceleration/Deceleration time =
(Acceleration/Deceleration time set
value) × (Frequency reference
value) ÷ (Max. frequency)
Used to set S-shape acceleration/de-
celeration characteristics.
0: No S-shape acceleration/decelera-
tion (trapezoidal acceleration/de-
celeration)
1: S-shape acceleration/deceleration
characteristic time 0.2 s
2: S-shape acceleration/deceleration
characteristic time 0.5 s
3: S-shape acceleration/deceleration
characteristic time 1.0 s
* When the S-shape acceleration/
deceleration characteristic time is
set, the acceleration and decelera-
tion times will be lengthened
according to the S-shape at the
beginning and end of acceleration/
deceleration.
Used to set internal frequency refer-
e ces
ences.
* Frequency reference 1 is enabled
in remote mode with n004 for fre
in remote mode with n004 for fre-
quency reference selection set to
1.
* These frequency references are
selected with multi-step speed ref-
p p
erences (multi-function input). See
(
l i f
i
i
the reference pages for the rela-
tionship between multi step speed
tionship between multi-step speed
references and frequency refer-
ences.
ences.
Used to set the inching frequency
command.
* The inching frequency command is
selected with the inching command
(multi-function input). The inching
frequency command takes prece-
dence over the multi-step speed
reference.
Set-
Unit
Default
ting
of
setting
range
set-
ting
0.0 to
0.1 s
10.0
6,000
(chan
ge in
n018)
n018)
10.0
10.0
10.0
0 to 3
1
0
0.01
0.0 to
6.00
max.
Hz
fre
fre-
(
(chan
0.00
quency
ge in
n035)
n035)
0.00
0.00
) S
0.00
0.00
0.00
0.00
6.00
Chapter 10
Changes
Ref-
during
er-
opera-
ence
tion
page
Yes
5-25
Yes
5-25
Yes
5-25
Yes
5-25
No
5-27
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-19
Yes
5-21

Hide quick links: