Data Write/Broadcast Data Write (Function Code: 10 Hex) - Omron SYSDRIVE 3G3MV SERIES User Manual

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV SERIES:
Table of Contents

Advertisement

Communications
D Response
Normal
Byte No.
1
Slave address
2
Function code
3
Number of bytes of attached data
Data in register No. 0020
4
5
6
Data in register No. 0021
7
8
Data in register No. 0022
9
Data in register No. 0023
10
11
12
CRC-16 check
13
Error
Byte No.
1
Slave address
2
Function code
3
Error code
4
CRC-16 check
5

7-3-2 Data Write/Broadcast Data Write (Function Code: 10 Hex)

H Settings and Response
• To write data to the Inverter, such as control I/O and parameter set value data, issue the following DSR
message.
• Consecutive data of a maximum of 16 words (32 bytes for 16 registers) can be written per DSR mes-
sage.
• The register number is allocated to each function item, such as control I/O and parameter functions.
The register number of each parameter is indicated wherever the parameter is explained in this
manual and in Section 10 List of Parameters. For register numbers other than those of parameters,
refer to 7-6 Register Number Allocations in Details.
Note 1. A parameter corresponds to one register (one word), so the "number of registers of write data"
indicates the number of parameters to be written (i.e., the number of consecutive registers
beginning with the first register number).
Note 2. The "number of bytes of attached data" indicates the number of bytes of data written to the
registers attached from that point onwards. The number of registers must equal the number of
bytes divided by two.
g
g
g
g
Data
Data
Chapter 7
Data
example
(Hex)
02
03
08
MS B
00
LSB
65
MSB
00
LSB
00
MSB
00
LSB
00
MSB
01
LSB
F4
AF
82
Data
example
(Hex)
02
83
03
F1
31
7-13