Advanced Operation
• If n115 is set to 1, the stall prevention level will be suppressed as shown below. When using frequen-
cies exceeding the maximum voltage frequency, set n 115 to 1.
Automatic Suppression of Stall Prevention Level (n115 Set to 1)
Operation level
n116
Stall Prevention
Acceleration/Deceleration Time
Setting
Setting
0, 1
range
Set Values
Value
0
Accelerates or decelerates at acceleration/deceleration time 1 or 2 presently selected.
1
Accelerates or decelerates at acceleration/deceleration time 2 set in n021 and n022.
• Select the acceleration/deceleration time with the stall prevention function operating function
enabled.
• To accelerate or decelerate quicker or slower than normal, set 1 in n116 and the acceleration time in
n021 (acceleration time 2) and deceleration time in n022 (deceleration time 2) for stall prevention use.
6-30
Constant output range
Max. voltage frequency (FA)
Register
Unit of
setting
Operating level: n094 x
(Max. voltage
frequency/output frequency)
0174 Hex
Changes during
operation
1
Set Values
Description
Chapter 6
Output frequency
No
0