1 Exchange capacities based on treating water containing 10 grains per gallon (171 mg/L) of hardness (expressed as calcium carbonate), free of color, oil, turbidity
and at a service flow rates not exceeding 20 gpm per square foot (49 m
characteristics, temperature, pressure and other factors.
2 Operation of a softener at peak flow rate for extended periods of time may result in a slight reduction of softening capacity. This is due to premature hardness
breakthrough.
NOTE: Operational, maintenance and replacement requirements are essential for this product to perform as advertised.
Specifications are shown for single models. Duplex models have two softener tanks and one brine tank system.
3
W
S
ATER
O
PERATING
1
Service Flow Rates
Peak
Press.
Drop
gr @ lb
gpm
psi
g @ kg
m
3
/hr
kPa
78
25
9,720/34
17.7
172
76
25
13,600/48
17.2
172
85
25
19,400/68
19.3
172
25
22.7
172
OFTENERS
D
ATA
2
Continuous
Press. Pipe Resin
Flow
Drop Size Qty.
gpm
psi
in
m
3
/hr
kPa
in
60
15
2
13.6
103
2
58
15
2
13.2
103
2
65
15
2
14.7
103
2
75
15
2
17.0
103
2
3
/m
2
/min) of bed area. These are nominal capacities and will vary with influent water