High resolution BGS sensor
BGS-HL Series
BGS-HL05T □
BGS-HL25T □□
Instruction manual
- Thank you for purchasing BGS-HL series. We hope you are satisfied with its performance.
- Please read this manual carefully and keep it for future reference.
Indicates a  possible hazard that may  result in  death,  serious 
injury, WARNINGS or serious property damage if the product is 
used without observing the stated instructions.
Warning       Mandatory Requirements
● The light source of this product applies the visible light semiconductor laser. Do not 
allow the laser beam to enter an eye, either directly or reflected from reflective object. If 
the laser beam enters an eye, it may cause blindness.
● This product is not an explosion proof construction. Do not use the product under flam-
mable , explosive gas or liquid environment.
● Do not disassemble or modify the product since it is not designed to automatically stop 
the laser emission when open. Disassembling or modifying at customer's end it may 
cause personal injury, fire or electric shock.
●Use of controls or adjustments or performance of procedures other than those specified 
herein may result in hazardous radiation exposure.
Warning     Safety Precautions
● It is dangerous to wire or attach/remove the connector while the power is on. Make sure 
to turn off the power before operation.
● Installing in the following places may result in malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil.
4. A place suffered from heavy vibration or impact.
● The product is not designed for outdoor use.
● Do not use the sensor in a transient state at power on (Approx. 2sec. Warm up period)
● Do not wire with the high voltage cable or the power lines.  Failure to do this will cause 
malfunction by induction or damage.
● Do not use the product in water.
● Operate within the rated range.
● Wipe off dirt on the emitting/receiving parts to maintain correct detection. Also, avoid 
direct impact on the product.
Precautions for using laser
● Regulations in the USA
When exporting laser devices to the USA, the USA laser control, FDA
(Food and Drug Administration) is applied. This product has been already
reported to CDRH (Center for Devices and Radiological Health). For
details, contact our customer service.
CLASS  2  LASER
CLASS  1  LASER
Complies with 21 CFR 1040.10 and 1040.11
PRODUCT
PRODUCT
except for deviations pursuant  to
laser notice No.50, dated June 24, 2007
MAX. OUTPUT    1mW
MAX. OUTPUT    390μW
OPTEX FA CO.,LTD.
WAVELENGTH = 655nm
WAVELENGTH = 655nm
91 Awata-cho Chudoji Shimogyo-ku Kyoto 600-8815 JAPAN
Place of manufacture :
EN/IEC 60825-1:2007
EN/IEC 60825-1:2007
OFROM CO.,LTD.
Complies with 21 CFR
Complies with 21 CFR
Manufactured in
1040.10 and 1040.11
1040.10 and 1040.11
except for deviations
except for deviations
pursuant to laser notice
pursuant to laser notice
No.50, dated June 24, 2007
No.50, dated June 24, 2007
Bundled goods in the box
Please confirm following goods bundled in the box.
・This instruction manual
・Screws
M3 × 15...2
・Bracket
Connection diagram
■ NPN type
■ PNP type
■ Pins configuration
・  M8 connector type
( sensor side )
Dimensions
■ Cable type
4.5 4core 2m Cable
■ M8 connector type
M8 4pin
Connector
Ramco Innovations
www.optex-ramco.com
Our email is nsales@ramcoi.com
Specifications
● Part number legend
Cable type
BGS-HL05T
Part 
Connector type
BGS-HL05TC
number
Sensing range
※ 1
20 ~ 50mm
(Display: 0.00 ~ 30.00)
Light source
Red laser Diode (wave length 655nm)
390μW
Laser
IEC/JIS
CLASS 1
class
Spot size
※ 2
φ 0.8 mm @ 50mm
Repeat accuracy
10μm
Sampling period
500μs / 1000μs / 2000μs / 4000μs / AUTO
Response time
1.5ms max. (1.5~7ms/default)
Hysteresis
0 ~ 22.49 (default: 0.15)
Display
7-segment 4-digit LED display
Indicator
Laser indicator: Green,
Output indicator: Orange, Mode indicator: Red
Control Output
NPN/PNP selectable
100mA max./DC24V (Residual voltage 1.8 V max.)
External Input
Laser OFF, Teaching, Sample Hold, One shot hold
Timer function
OFF/On delay/Off delay/One shot
1msec increment : 0 ~ 9999ms
Supply voltage
12 ~ 24VDC including 10% ripple
Current consumption
40mA max. / 24VDC excluding the current of Control Output
Protection circuit
Reverse connection protection, Over current protection
Protection category
Operating Temp./Humid.
-10 ~ 50℃ / 35 ~ 85% RH without freasing or condensation
Storage Temp./Humid.
-20 ~ 60℃ / 35 ~ 85%/RH
Ambient illuminance
Incandescent lamp: 3,000 lx max.
Vibration resistence
10 ~ 55Hz, Double amplitude 1.5mm, X,Y,Z for 2 hours
2
Shock resistence
500m/s
( approx. 50G) X,Y,Z 3 times each
Material
Case: Aluminum, Front lens: PPSU, Display: PET
Weight
Cable type : Approx. 90g (including cable)
Connector type : Approx. 30g
The specifications are based on the condition unless otherwise designated: Ambient temperature: 23℃ , Sup-
ply voltage: 24VDC, Sampling period: 500µs, Averaging: 512, Measuring distance: Center of the range, Testing 
object: White ceramic
[mm]
※ 1  When [Shift] in Extension mode is ON, the display shows 0000 at the Teaching point.
The range that the display can show is as follows.
BGS-HL05     -7.50 ~ 37.50
BGS-HL25     -50.0 ~ 250.5
           When the distance exceeds this range in Sensing range, the display shows FFFF. Although, the sensor
           works while the distance is in Sensing range. The display shows 9999 when the distance is out of range.
2
※ 2  Defined by light strength within 1/e
(13.5%) of spot center. There may be leak light at outside of the
specified spot size. The sensor may be affected when there is a highly reflective object at that leak light
          area.
μs
※ 3  Sampling period : 1000
.
Display
Functions of components
● Control panel
Display
Got Questions? 1-800-280-6933
Setup
● Changing mode
While it's "Setup mode" or "Extension mode", you can change the mode to "RUN mode" 
by clicking "TEACH/RUN" button.
While it's "Extension mode", the LED "MANUAL" is lit.
BGS-HL25T2
BGS-HL25TC2
50 ~ 250mm
(Display: 0.0 ~ 200.0)
1mW
CLASS 2
φ 1 mm @ 250mm
100μm
※ 3
1.5ms max. (3~14ms/default)
0 ~ 149.9 (default: 1.0)
● Changing parameters
You can choose and adjust the parameters by clicking "+" and "-" buttons.
The mode will be changed to "RUN mode" by clicking "TEACH/RUN" button.
IP67
Teach function
You can change threshold level directly by "+" and "-" buttons after clicking "TEACH/
RUN" button from "RUN mode".
By pressing "TEACH/RUN" button for 2 seconds or more, it gets to "Teaching mode". It 
has 3 "Teaching mode" that you can choose one in "Setup mode".
Please refer "Teaching mode" and "Setup mode" on next page.

Advertisement

loading

Summary of Contents for Fastus BGS-HL Series

  • Page 1 Need Technical Support or Help with a Tough Application? Contact the experts at Ramco today! Our email is nsales@ramcoi.com Specifications Setup Connection diagram ● Part number legend High resolution BGS sensor ● Changing mode BGS-HL Series ■ NPN type While it's "Setup mode" or "Extension mode", you can change the mode to "RUN mode"  by clicking "TEACH/RUN" button. While it's "Extension mode", the LED "MANUAL" is lit. BGS-HL05T □ BGS-HL25T □□ Instruction manual - Thank you for purchasing BGS-HL series. We hope you are satisfied with its performance.
  • Page 2 Teaching mode Setup mode Extension mode Miscellaneous function You can get to [Setup mode] by clicking "SET" button from [RUN mode]. (* means default value) You can get to [Extension mode] from [2:Extension mode] in [Setup mode]. (* means default value) BGS-HL series has 3 Teaching mode. Please choose a Teaching mode at [Teach mode ] in [Setup mode] before Teaching. Output polarity can be reversed by [Light ON/Dark ON  Ldon  ]. Following output shows its ON/OFF status as [Light ON   ]. L on diSP ● 1 point Teaching ZonE Teaching is done at a position on the object to detect. When the distance is closer than that position,  the output will be ON. rESt Press  the  [TEACH/RUN]  button  until  the  display  shows  “1pt”.  Teaching is completed after releasing button. NEnu uLoc ShiF Dimensions with bracket [mm] ■ Cable type with standard bracket BGS-HL-B 200. 0 0.