Frequency: Recommended about twice a year. Units that are used heavily or are on highly mineralized water
may require more frequent cleaning.
Cleaning this machine involves adding a solution of scale remover and water to the ice machine and continuing
to add it as it makes ice. The scale remover must be diluted to the correct ratio. This is followed by sanitizing.
The ice machine must be connected to power, water and drain during this process. Recommended tools:
Rubber gloves, small scrub brush & scale remover.
1. Remove the top panel for reservoir access.
Note: If the unit must be pulled out to remove the panel and access the water reservoir, be sure that the water
supply, drain and power remain connected
2. Remove the front panel for control access.
3. Scoop out and discard all of the ice.
4. Press and hold the Off button until the machine shuts off.
5. Locate float valve on/off lever. Rotate to shut water supply OFF.
6. Push tab on front edge of reservoir cover and remove the cover.
Note: Adjacent wires are low voltage and are not hazardous.
7. Locate drain plug and pull the drain plug out to drain the reservoir and evaporator. When draining is
complete, return the plug to its original position.
8. Mix a solution of Clear 1 scale remover with water: 2.5 ounces of Clear 1 with 1 quart (32 oz) of warm
(90
F/32
C to 110
F/43
0
0
0
Note: Take care not to spill any scale remover on any nearby surface. Immediately wipe any spill with baking
soda and water.
9. Fill the reservoir with the scale remover solution. That will be about 8 ounces.
10. Unscrew (rotate CCW) and remove the ice sweep.
11. Wash the ice sweep and lower part of the breaker with the scale remover solution. Remove as much scale
as possible.
12. Return the ice sweep to its original position.
13. Press and HOLD the both the On and Off buttons for 5 seconds. The Time to Clean light will blink on and
off.
The auger motor will be operating for 20 minutes, after that the compressor will start and in about 5-8 minutes
the machine will start to make ice. The Time to Clean light will now glow steady until the clean cycle is
complete.
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner comes
in contact with skin, flush with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.
C) potable water.
0
Caution: Be SURE no scale remover contacts the bearing.
Caution: Keep fingers away from moving parts.
October 2019
Page 15

Advertisement

loading

Summary of Contents for Scotsman UF0915

  • Page 1 UF0915, 1415, 2020 and UN0815, 1215, 1520 User Manual Maintenance: Cleaning The Water System Frequency: Recommended about twice a year. Units that are used heavily or are on highly mineralized water may require more frequent cleaning. Cleaning this machine involves adding a solution of scale remover and water to the ice machine and continuing to add it as it makes ice.
  • Page 2 UF0915, 1415, 2020 and UN0815, 1215, 1520 User Manual 14. After ice making starts, continuously add scale remover solution to the reservoir to keep it about half full. 15. When all remaining solution is used, rotate the float valve lever to the ON position. Ice will continue to be made.
  • Page 3 UF0915, 1415, 2020 and UN0815, 1215, 1520 User Manual Cleaning the Condenser 1. Remove the front panel. Other maintenance 2. Push and hold the OFF button until the machine Clean the optical sensors. stops and / or the Status light is not glowing.
  • Page 4 UF0915, 1415, 2020 and UN0815, 1215, 1520 User Manual Other maintenance Clean the optical sensors. 1. Mix solution of 4 ounces of Clear 1 Ice Machine 4. Use cotton swab and cleaning solution to Scale Remover and 1.5qt/1.4L of 90...

This manual is also suitable for:

Uf1415Uf2020Un0815Un1215Un1520Uf0915a-1