Download Print this page

Fastus TOF-DL250 Series Instruction Manual

Long distance bgs laser sensor

Advertisement

Quick Links

Contact Ramco for technical and application support 
Long Distance BGS Laser Sensor
TOF-DL250 series
・TOF-DL250□□
INSTRUCTION MANUAL
● Thank you for purchasing TOF-DL series. We hope you are satisfied
with its performance.
● Please read this manual carefully and keep it for future reference.
■Safety Symbols
The safety symbols and their meanings are as follows.
Indicates that any improper operation or handling may result in moderate or minor injury,
Warning
and in rare cases, serious injury or death. Also indicates a risk of serious property damage.
Indicates that any improper operation or handling may result in minor injury or
Caution
property damage.
Warning
Do not disassemble, repair, modify, deform under pressure, or attempt to incinerate this product.
Doing so may cause injury or fire.
This product is not explosion-proof and should not be used around flammable or explosive gases or 
liquids. Doing so may cause ignition resulting in a fire.
Do not use air dusters or any spray that uses flammable gas around the product or on the inside of 
the product. Doing so may cause ignition resulting in a fire.
Do not install this product in any of the following locations.
Doing so may cause a fire, damage, or a malfunction.
1. Locations where dust, salt, iron powders, or vapor (steam) is present.
2. Locations subjected to corrosive gases or flammable gases.
3. Locations where water, oil, or chemical splashes may occur.
4. Locations where heavy vibrations or impacts may occur.
5. Locations where the ambient temperature exceeds the rated range.
6. Locations subject to rapid temperature changes (or where condensation occurs).
Do not use this product in a non-industrial environment. 
Doing so may cause induction or radiation interference.
In the event of a malfunction such as smoke comes out from the product
If you detect any malfunction including emission of smoke, abnormal smells or sounds, or the housing 
becoming very hot, immediately stop operating the product and turn off the power to the controller. 
Doing so may cause a fire. Repairing the product is dangerous and should in no way be performed by 
the customer. Contact the Optex FA sales office.
In case water enters the product
If water or any other liquid enters the product, immediately stop operating the product and turn off 
the power to the controller.  Using the product in this condition may cause a fire.
Caution
Do not drop the product or subject the product to strong impacts. Doing so may damage the product.
The light source of this product applies the visible light semiconductor laser. Do not allow the laser beam to enter an 
eye, either directly or reflected from reflective object. If the laser beam enters an eye, it may cause damage or problems 
of the eye.
Follow the instructions in this manual or the specified instruction manual when wiring the product for the correct
wiring method. Incorrect wiring can damage the product or cause a malfunction. Output cannot be connected with
other LED controller in series nor in parallel.
Do not excessively twist or apply stress to the cable.
Doing so may damage the cable or the connector.
When connecting the cable, make sure to hold it by the connector portion, and do not apply excessive force to the cable.
When disconnecting the connector, be careful not to touch the terminals inside the connector, and do not
allow foreign objects to enter the connector.
Route wiring separately from high-voltage circuits and power circuits.
If the wires are routed together, induction may occur, which can cause a malfunction or damage the product.
If this is unavoidable, use a conductive object such as a properly grounded conduit as a shield.
Install this product as far away from high-voltage equipment, power equipment, equipment that generates
large switching surges, welders, inverter motors, or any equipment that can be a source of noise.
Use the product within the rated ranges.
Install this product and the dedicated controller securely.
Failure to ensure secure installation can result in the products falling and becoming damaged.
Make sure to turn the power off before connecting or disconnecting the cable.
Connecting or disconnecting while energized may damage the product.
Donʼt bend the cable when the temperature of the cable or atmosphere is below freezing.
Donʼt use the sensor on transient state after power on (approx. 300ms).
The sensor performance or digital display values may depend on the individual units or the condition of detecting object.
Precautions for using laser
This product is classified as Class 1 Laser Product by
JIS C6802 :2014/IEC60825-1 :2007 and 2014 Laser
Safety Standard.
When exporting this product to USA, it's necessary to
follow laser regulation of USA FDA. This product has
been already reported to CDRH (Center for Devices
and Radio-logical Health). For details, contact our
customer service.
Ramco Innovations www.optex-ramco.co
  
     
7. Locations with strong electric or 
    magnetic fields.
8. Outdoor locations or locations 
    subject to direct sun light.
SPECIFICATIONS
Type
M8 Connector Type
2m Cable Type
5m Cable Type
M12 Pig-tail Type
Sensing distance
(Reflectance: 6% Black
Red laser diode (wave length: 650nm, maximum output: 64mW,
Light source
Laser class
Spot size*
2
Hysteresis
15% Max. (Reflectance: 6% Black paper/18% Gray paper/90% White paper)
Sampling period
Response time
Indicator
Stable indicator (Green LED)/Unstable indicator (Red LED)
Digital display
Threshold adjustment
Output mode
NPN/PNP (selectable by setting) open collector DC30V,
Control output
External input
Analog output
Voltage: 0~10V (selectable by setting)
Power supply
DC12~30V including ripple (P-P)10%*
Current consumption
EMC
Applicable
RoHS Directive (2011/65/EU), China RoHS(MIIT Order No.32)
RoHS
regulations
Safety
Applicable standards
EN 60947-5-7 / IEC 60825-1
Cross talk prevention
Reverse connection protection, Over current protection
Protection circuit
Ambient Temp./Humid.
Storage Temp./Humid.
Sun light
Ambient
illuminance
Incandescent light
Vibration resistance
Shock resistance
Protection category
Material
M8 connector type: approx. 30g, 2m cable type: approx. 88g,
Weight including cable
5m cable type: approx. 188g, M12 pig-tail type: approx. 48g
Accessories
1 mounting bracket: BEF-WK190, 2 screws: M3x20mm
*1 These products are Classified as CLASS 1 by IEC 60825-1: 2007 according to Laser Notice No.50,
FDA Guidance Document.
*2 Defined with center strength 1/e
2
(13.5%) at the center. There may be leak light other than the specified spot size.
The sensor may be affected when there is a highly reflective object close to the detection area.
*3 Analog output type have 2 lit at same time. M8 connector type (TOF-DL250DC) has 2 for 2 control outputs.
*4 Analog output type have 1. M8 connector type (TOF-DL250DC) has 2. Other types have 3 control outputs.
*5 Use power supply with DC12.0V Min. to get sufficient output for analog output.
*6 Excluding load current for control output.
*7 Except for deviations pursuant to laser notice No.50.
800-280-6933
Analog Output Type
Control Output Type
TOF-DL250AC
TOF-DL250A
TOF-DL250A-5
TOF-DL250AM12
TOF-DL250TM12
0.25 ~ 2.5m
paper/18% Gray
 
pulse duration: 7ns, repetition rate: 11.11MHz)
average output: 390μW Max.
CLASS 1(IEC/JIS/FDA*
Φ10mm /2.5m
200μS
0.5ms Max. (averaging number: 1)
Output indicator (Orange LED*
(All LED will be OFF when Laser is OFF)
7 segment 3 digit (unit: cm)
Teaching and +/- buttons
Light ON  / Dark ON selectable by setting
 
100mA max. (Residual 1.8V max)*
Laser OFF, External teaching
 
: 4~20mA/
Current
5
DC10~30V including ripple (P-P)10%
6
60mA Max.*
EMC Directive (2014/30/EU)
FDA Regulations (21 CFR 1040.10 and 1040.11*
EN 60947-5-2 / IEC 60825-1
Up to 2 units
-10~50℃/35~85%RH (no condensation)
-40~70℃/35~95%RH (no condensation)
4,000lx Max. at receiving window
3,000lx Max. at receiving window
10~55Hz amplitude 1.5mm X,Y,Z  each 2h
2
500m/s
 X,Y,Z  each 3 times 
IP67
Case: PC  / Lens: PMMA
nsales@ramcoi.com
TOF-DL250DC
TOF-DL250T
TOF-DL250T-5
/90% White
)
 paper
 paper
1
3
)/
4
7

Advertisement

loading

Summary of Contents for Fastus TOF-DL250 Series

  • Page 1 Contact Ramco for technical and application support  SPECIFICATIONS Type Analog Output Type Control Output Type Long Distance BGS Laser Sensor M8 Connector Type TOF-DL250AC TOF-DL250DC 2m Cable Type TOF-DL250T TOF-DL250A TOF-DL250 series TOF-DL250A-5 TOF-DL250T-5 5m Cable Type TOF-DL250AM12 TOF-DL250TM12 M12 Pig-tail Type    0.25 ~ 2.5m Sensing distance (Reflectance: 6% Black paper/18% Gray /90% White ・TOF-DL250□□          paper  paper Red laser diode (wave length: 650nm, maximum output: 64mW, Light source pulse duration: 7ns, repetition rate: 11.11MHz) INSTRUCTION MANUAL average output: 390μW Max. CLASS 1(IEC/JIS/FDA* ) Laser class ● Thank you for purchasing TOF-DL series. We hope you are satisfied Spot size*...
  • Page 2 Circuit diagram   ■Analog output type ■Control output type ■NPN mode ■NPN mode When used as output DC10~30V DC12~30V When used as output Load Load Load Load Control Control output 1 output Control output 2 External input Control output 3 When used as input Analog output When used as input ■PNP mode ■PNP mode DC10~30V DC12〜30V When used as input When used as input Control output Control output 1 Control output 2 External input Control output 3 Analog output When used as output When used as output...
  • Page 3 Name of the parts and setup Dimensions ●Without mounting bracket [ mm] Name and function of buttons and indicators vary depends on the model. ■ Cable type, M12 pig-tail type TOF-DL250A TOF-DL250AC TOF-DL250AM12 32.8 TOF-DL250A-5 Display Receiver Emitter Output indicator (orange) + (2 indicators lit at same time) Stable indicator (stable: green/ − unstable: red), OFF when laser is OFF TOF-DL250T TOF-DL250TM12 TOF-DL250T-5 Φ4.5 5 core 2m/5m cable  Display Φ4.5 M12 5 pin 300mm pig-tail cable ■ M8 connector type Output indicator 2 (orange) Output indicator3(orange) + Stable indicator (stable: green/ unstable: red), OFF when laser − is OFF M8 4pin connector Output indicator 1(orange) ●With mounting bracket ■ Cable type, M12 pig-tail type TOF-DL250DC Display Output indicator 2 (orange) 11.7...
  • Page 4 Extension mode You can get to “Extension mode” by clicking “RUN” button or “SET” button. (“ ” means default value) ■8. Display Select ON/OFF of the display ■1. External input (MF input) ON: Activate the display (unit: cm) (*) Press “SET” to get to setting menu + OFF: Darken the display when there is no button operation −           over 30 seconds Set function of external input Disable external input (neglect the input) ■9. Delay + Set delay function for output on detection Use as output (as following table) − Not use delay function (*) Model Target output + OFF delay: Delays output timing TOF-DL250A TOF-DL250AM12 −                     of ON to OFF applicable TOF-DL250A-5 TOF-DL250AC Output 1 ON delay: Delays output timing Input value                     of OFF to ON TOF-DL250T TOF-DL250TM12 Range: 0~999 Output 3 TOF-DL250T-5 Default: 0 One shot: Output ON for the...

This manual is also suitable for:

Tof-dl250acTof-dl250aTof-dl250a-5Tof-dl250am12Tof-dl250tTof-dl250t-5 ... Show all