NOTE: Control Box #0 and #1 are designed for routine 171°F (77°C)
disinfection cycles up to 30 minutes.
Control Box #8 is not recommended for high temperature disinfection
cycles as the thermostatic mixing valve limits the higher temperature
flow output.
NOTE: For optimum performance of this product, we recommend
a system pressure between 20 and 80 PSI static. This product
will operate up to a maximum of 125 PSI static per ANSI and CSA
requirements. However, we do not recommend pressure above
80 PSI. Thermal expansion or leaking pressure reducing valves
may require use of expansion tanks or relief valves to ensure
your system never exceeds its maximum intended pressure
setting.
1.5 GPM (5.7 L/min)
063202A (R5)
063203A (R7)
063204A (R35)
2.2 GPM (8.3 L/min)
063240A (R5)
063241A (R7)
063242A (R35)
Single-Hole Mount
Assembly including
Smooth-End Spout
with Sensor & Gasket
(see correct RP # for
proper flow control
adaptor A & B,
ordered separately)
060905A
Cover Gasket
060906A
Surface
Mount Housing
061252A
Dual Driver Board
Masco H 2 Optics
& Proximity
063258A
Surface Box Assembly (less driver board)
w/ 3/4" solenoid and adaptors for 3/8" compression
*Package Quantities May Change.
Check the Parts section of the latest Delta Commercial Faucet Price List for current quantities.
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
060637A
1.5 GPM (5.7 L/min)
VR Laminar Outlet
with Antimicrobial
®
by Agion
060639A
1.5 GPM (5.7 L/min)
VR Flow Control
Aerator & Wrench
063160A
Thin Mount Kit
(3/8" Elbow, Nut,
Washer & Gasket)
Note: See page 3 for parts breakdown
OR
on recessed mount boxes.
063162A
1.5 GPM (5.7 L/min)
063244A
2.2 GPM (8.3 L/min)
Adaptor with Flow Control
063257A
3/4" Solenoid Valve
w/adaptors for 3/8"
Compression
060908A
Solenoid Holder
w w w . s p e c s e l e c t . c o m
150__T4 __ __ __
Write purchase model number here for future reference
063207A (R5)
063208A (R7)
063209A (R35)
Single-Hole Mount
Assembly including
Sensor, Gasket &
Spout with Aerator
Thread
063161A
Thick Mount Kit
(Nut, Washer, Gasket,
Shank, 1/4 NPT Pipe
& 3/8" Compression
Fitting)
061256A
060683A
36" Cable
24VAC to 6VDC
Extension
Converter
062032A
Braided Polymer Hose
Page 1
Fig. 1
OPTION LIST
060681A
Battery Holder
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
A
063163A
1.5 GPM (5.7 L/min)
063243A
2.2 GPM (8.3 L/min)
Bushing with Flow
Control
#7 Smooth
End Spouts
(to be used with
only
Control Box #'s
1 & 8)
B
#7 Smooth End
Spouts only
063162A
1.5 GPM (5.7 L/min)
063244A
2.2 GPM (8.3L/min)
Adaptor with Flow Control
(to be used with Control Box #0)
212193 Rev. C

Advertisement

Table of Contents
loading

Summary of Contents for Delta 150 T4 Series

  • Page 1 3/4” solenoid and adaptors for 3/8” compression *Package Quantities May Change. Check the Parts section of the latest Delta Commercial Faucet Price List for current quantities. PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as items relating to ongoing maintenance suggestions and procedures are included.
  • Page 2: Installation And Set Up Instructions

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. INSTALLATION AND SET UP INSTRUCTIONS FOR SURFACE MOUNT HOUSING: CONTROL BOX #0 STEP 1. FAUCET INSTALLATION Depending on the installation, use the 063160A thin wall kit OR 063161A thick wall kit (both provided as standard).
  • Page 3: Step 1. Rough In

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8 STEP 1. ROUGH IN Note: Wires connecting between box(es) and from transformer must be protected from abrasion, and being pulled at connections. They also may have to be fished through at a later stage of construction.
  • Page 4 INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING: CONTROL Fig. 8 Typical Installation BOXES #1 & 8 (Recessed Mount Box) Gooseneck Spout STEP 3. CONNECT WATER SUPPLY Install sink and connect drainage to rough in. See applicable Fig. 6 or Fig. 7. Please note that the connection and fittings are supplied by the installer to connect 1/2”...
  • Page 5: Step 8. Making Adjustments

    INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8 Operation Illustration STEP 7. TEST FOR OPERATION Test for operation. If unit does not work properly, see Troubleshooting Guide on page 7. STEP 8. MAKING ADJUSTMENTS If adjustments are required.
  • Page 6: Battery Strength Indicator

    ● bAd - Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on). Faucet will disable itself if batteries are not replaced. If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical Services at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).
  • Page 7: Care Instructions

    CARE INSTRUCTIONS This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards. With proper care, it will give years of trouble free service. Care should be given to the cleaning of this product. Although the chrome finish is extremely durable, it can be DAMAGED by ACIDIC CLEANERS (i.e.
  • Page 8 Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. WARNING CAN ICES-3 (A) / NMB-3(A) 2023 Masco Canada Ltd. © For further technical assistance, call Delta Commercial Technical Service at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.). 255069, Rev H 212193 Rev. C Page 8...

This manual is also suitable for:

1501t46701500t46101500t4670-r351500t46781500t46201500t4628

Table of Contents