Trane BAYHALT230 Installer's Manual
Trane BAYHALT230 Installer's Manual

Trane BAYHALT230 Installer's Manual

High altitude conversion kits

Advertisement

Quick Links

INSTALLER'S
GUIDE
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
Model:
BAYHALT230
BAYHALT235
BAYHALT231
BAYHALT236
BAYHALT232
BAYHALT237
BAYHALT233
BAYHALT241
BAYHALT234
BAYHALT242
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
A. GENERAL
These high altitude conversion kits are to be used only
with furnace model numbers *UX-C, *DX-C, *UX-R, *DX-R,
*UY-R, and *DY-R series.
These instructions describe the conversion of these
furnaces for installation exceeding an altitude of 4000 feet
above sea level.
Due to the lower density of air at higher altitudes, there
would be insufficient negative pressure developed by
the induced draft blower to maintain normal operation.
Therefore, to compensate for the less dense air, pressure
switches must be changed to prevent nuisance lockouts
and/or cycling of the reduced draft blower on high
speed. Please note that with the reduced firing input
rates required for high altitude installations, the induced
draft blower has ample capacity to provide sufficient
combustion air for proper and safe operation. Refer to the
National Fuel Gas Code, Section 8.1.2 and Appendix F, for
information regarding the correct procedure to derate the
furnace's input. The following instructions must be followed
to convert these furnaces for high altitude applications.
B. CONVERSION
The instructions below apply to *UX-C, *DX-C, *UX-R-V,
*DXR-V, *UY-R9V-A, *DY-R9V-A, *UY-R9V-V and *DY-
R9V-V furnace product lines.
1. Check for damage to kit contents, and check for all
items listed in the table.
2. Disconnect electrical supply to furnace, if installed.
3. Remove the wiring connections from the pressure
switch(es) in the furnace. Mark the wires if needed to
properly identify the replacement.
4. Remove the pressure switch(es) sample tube from the
switch assembly.
5. Remove the pressure switch from the unit.
6. Install the new pressure switch in the same location
and manner as the old pressure switch.
7. Connect the pressure switch sample tube and
electrical connections.
* - First letter may be "A" or "T"
BAYHALT245
BAYHALT246
BAYHALT247
HIGH ALTITUDE
CONVERSION KITS
or *UX-C, *DX-C, *UX-R, *DX-R, *UY-R, and *DY-R
f
Furnace Models
8. Reconnect the electrical supply to the unit.
C. CHECKOUT
Once the furnace has been correctly rated for the high
altitude installation, and the pressure switch has been
changed, the furnace installation shall be checked for
proper installation and performance. Refer to the unit
Installer's Guide for checkout procedure.
D. NOTES
1. The use of high altitude calibrated pressure switches
in sea level applications is not permitted.
2. The high altitude pressure switches are factory
calibrated and sealed. Field adjustment is not
permitted. If the factory seal is broken, the product
warranty may be voided.
KIT CONTENTS:
HIGH ALTITUDE CONVERSION KITS
Kit Model
Furnace
No.
*UX040C, *DX040C,
BAYHALT230
*DX060C-A0 thru B1,
*UX100C960
BAYHALT231
*UX060C
BAYHALT232
*UX080C
*UX100C948, *UX120C,
BAYHALT233
*DX080C, *DX120C,
*DX100C-C4 and later
BAYHALT234
*DX100C-A0 thru C3
*UY060R-A, *UY080R-A,
BAYHALT235
*DY080R-A, *DY120R-A
BAYHALT236
*UY100R-A
BAYHALT237
*DY100R-A
BAYHALT241
*DX060C-B2 and later
BAYHALT242
*UY120R-A
UY060R-V, *UX060R-V,
BAYHALT245
*DY060R-V, *DX060R-V
*UY080R-V, *UX080R-V,
*DY080R-V, *DX080R-V,
BAYHALT246
*UY100R-V, *UX100R-V,
*DY100R-V, *DX100R-V
*UY120R-V, *UX120R-V,
BAYHALT247
*DY120R-V, *DX120R-V
* - First letter may be "A" or "T"
18-CH12D24-3A-EN
Contents
Models
1 - Pressure Switch
1 - Pressure Switch
1 - Pressure Switch
1 - Pressure Switch
1 - Pressure Switch
2 - Pressure Switch
2 - Pressure Switch
2 - Pressure Switch
1 - Pressure Switch
2 - Pressure Switch
2 - Pressure Switch
2 - Pressure Switch
2 - Pressure Switch

Advertisement

loading

Summary of Contents for Trane BAYHALT230

  • Page 1 INSTALLER'S 18-CH12D24-3A-EN GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES HIGH ALTITUDE Model: BAYHALT230 BAYHALT235 BAYHALT245 CONVERSION KITS BAYHALT231 BAYHALT236 BAYHALT246 BAYHALT232 BAYHALT237 BAYHALT247 or *UX-C, *DX-C, *UX-R, *DX-R, *UY-R, and *DY-R BAYHALT233 BAYHALT241...
  • Page 2 Installer's Guide About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

This manual is also suitable for:

Bayhalt231Bayhalt232Bayhalt233Bayhalt234Bayhalt235Bayhalt236 ... Show all