[Basic parameter list]
No.
Title
Function
Automatic
1
acceleration/deceleration
2
Automatic V/f mode setting
Operation command mode
3
selection
Speed setting mode
4
Selection
5
FM terminal meter selection
FM terminal meter
6
adjustment
Standard setting mode
7
selection
Forward/reverse selection
8
(At panel control only)
9
Acceleration time #1
10
Deceleration time #1
11
Maximum frequency
12
Upper limit frequency
13
Lower limit frequency
14
Base frequency #1
Motor control mode
15
selection
16
Manual torque boost
Selection of electronic
17
thermal protection
characteristics
18
Preset-speed # 1
19
Preset-speed # 2
20
Preset-speed # 3
21
Preset-speed # 4
22
Preset-speed # 5
23
Preset-speed # 6
24
Preset-speed # 7
25
Extended parameter
∼
26
Automatic edit function
Adjustment range
: Manual acceleration/deceleration
: Automatic acceleration/deceleration
:−(0 is always displayed.)
: Automatic torque boost + auto-tuning
: Sensorless vector control (speed) + auto-tuning
: Automatic energy-saving + auto-tuning
: Terminal block enabled
: Operating panel enabled
: Common serial communication option enabled
: Serial communication RS485 enabled
: Communication add-on cassette option enabled
: VI (voltage input)/II (current input)
: RR (volume/voltage input)
: RX (voltage input)
: RX2 (voltage input) (optional)
: Operating panel input
: Binary/BCD input(optional)
: Common serial communication option(FA01)
: Serial communication RS485(FA05)
: Communication add-on cassette option(FA07)
: Up-down frequency
: Pulse input #1 (optional)
∼
−
:−
: 50Hz standard setting
: 60Hz standard setting
: Factory default setting
: Trip clear
: Clearing accumulating operation time
: Initialization of type form information
: Memorization of user-defined parameters
: Reset of user-defined parameters
: Forward,
: Reverse
()∼ [s]
()∼ [s]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
: Constant torque
: Variable torque mode
: Automatic torque boost
: Sensorless vector control (speed)
: Automatic torque boost + automatic energy-saving
: Sensorless vector control (speed) + automatic energy-saving
: V/f 5-points setting
:Sensorless vector control (speed/torque switching)
: PG feedback vector control (speed/torque switching)
: PG feedback vector control (speed/position switching)
∼ [%]
Setting
Type
Overload protection
Standard
motor
not protect
not protect
VF motor
(special
not protect
motor)
not protect
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
Setting of extended
To search parameters different from default value.
D-3
Overload stall
protect
not stall
protect
stall
not stall
stall
protect
not stall
protect
stall
not stall
stall
Default
Reference
setting
section
5.1.1
5.2
5.3
5.3
5.4
−
5.4
5.5
5.6
See J-28
5.1.2
See J-28
5.1.2
5.7
5.8
5.8
5.9
5.10
See J-28
5.12
5.13
5.14
4.1.2
−
−
4.1.2